Section 5-3
Procedure 14
- Oven Vents
Step 1: Remove oven door
(Procedure 33)
Step 2: Oven vents are located in
the top of the oven.
Note: Vents have a grid called a
smoke eliminator positioned at the
bottom of the oven vent. Do not
remove this component.
Step 3: Inspect opening to vent for
signs of excessive foreign
substances
Step 4: Pull unit away from the wall
Step 5: Remove top cresting
splashback and inspect the vent -
ensure vents have appropriate
clearance. If blocked or not level,
replace.
Step 6: To replace oven vent,
remove screws holding oven vent to
oven cavity from inside oven
Step 7: Remove stove's back
panel (Procedure 32).
Step 8: Transfer insulation around
vent tube to new oven vent.