Download Print this page

Heartland Appliances Metro Service Manual page 18

Advertisement

Procedure 2
Step 1: Disconnect power supply
to range. Pull range away from wall.
Step 2: Remove back panel. Refer
to Procedure 32 for details.
Step 3: Inspect terminal block for
burnt terminal connections. If
damaged, replace.
Step 4: To replace terminal block,
remove power cord by unscrewing
the three screws that retain the
ends of the cord to the terminal
block.
Step 5: Mark and disconnect all
wires attached to the terminal block
(including wire to ground stud for 4
prong power cords)
- Terminal Block
Step 6: Terminal block can be
removed from range by removing
the two center screws.
Step 7: Install new terminal block,
attach all red, white and black wires
as originally marked
Step 8: Attach power cord back on
terminal block. Be sure all wires are
secure. 3 prong power cords have
jumper cable from center (neutral)
side of terminal block to stud. 4
prong power cords have copper
wire from cord directly attached to
ground stud.
18
Section 5-3
MLSM2003-01-03

Advertisement

loading

This manual is also suitable for: