Traction And Pump Control Input / Output List - GE IC3645SR4W606MC2 Installation And Operation Manual

Separately excited (sx) transistorized traction motor control and series pump motor control
Table of Contents

Advertisement

OUTLINE DRAWINGS, ELEMENTARY DRAWINGS AND INPUTS/OUTPUTS
SX TRANSISTOR CONTROL
Section 3.10 Traction and Pump Control Input and Output List
PIN
INPUT/OUTPUT DESCRIPTION
1
BATTERY VOLTS FROM BATTERY
2
BATTERY VOLTS FROM KEY
3
BATTERY VOLTS FROM START SWITCH
4
BATTERY VOLTS FROM FORWARD SWITCH
5
BATTERY VOLTS FROM REVERSE SWITCH
6
BATTERY VOLTS FROM SEAT SWITCH
7
ACCELERATOR INPUT VOLTAGE SIGNAL
8
ACCELERATOR NEGATIVE
9
ACCELERATOR POT +5 VOLTS SUPPLY
10
BDI INTERRUPT
11
1A DRIVER SIGNAL
12
SPEED LIMIT B+
13
NOT USED
14
HYDRAULIC SWITCH SENSOR
15
I
OUT
MOTOR
16
MOTOR CURRENT COMPENSATION
17
LINE CONTACTOR DRIVER AND SUPPRESSION
18
STEER PUMP CTR DRIVER AND SUPPRESSION
19
TMM + 5 VOLT SUPPLY
20
NOT USED
21
HOURMETER INPUT
22
+12V FOR TACHOMETER
23
TACHOMETER
MOTOR PROPORTIONING "Y" PLUG
PIN
INPUT/OUTPUT DESCRIPTION
1
CLOCK (OUT)
2
DATA (OUT)
3
ENABLE (OUT)
4
NEGATIVE
5
+5V SUPPLY
6
CONT/STORE (IN) (HANDSET)
7
TACHOMETER
8
VALUE
9
FUNCTION
10
+12 VOLTS
11
SERIAL RECEIVE
12
SERIAL TRANSMIT
1
2
3
4
5
6
7
8
9
10
11
12
WIRE END VIEW "Y" PLUG
CONNECTIONS TO MAIN PLUG (23 PIN) AND "Y" PLUG (12 PIN)
TRACTION
1
2
3
4
5
9
10
11
12
13
16
17
18
19
20
WIRE END VIEW - MAIN PLUG
INPUT/OUTPUT DESCRIPTION
BATTERY VOLTS FROM BATTERY
BATTERY VOLTS FROM KEY
STATUS CODE 93 INPUT
STATUS CODE 93 INPUT
STATUS CODE 94 INPUT
STATUS CODE 94 INPUT
POTENTIOMETER INPUT VOLTAGE SIGNAL
STATUS CODE 95 INPUT
STATUS CODE 95 INPUT
PUMP ENABLE SIGNAL 12VDC
STATUS CODE 91 INPUT
SPEED LIMIT #1 INPUT
TMM1 BRUSHWEAR INDICATER OUTPUT
TMM1 OVER TEMPERATURE OUTPUT
STATUS CODE 92 INPUT
STATUS CODE 90 INPUT
LINE CONTACTOR DRIVER
1A CONTACTOR DRIVER
SPEED LIMIT #2 INPUT
SPEED LIMIT #3 INPUT
SPEED LIMIT #4 INPUT
NOT USED
NOT USED
INPUT/OUTPUT DESCRIPTION
CLOCK (OUT)
DATA (OUT)
ENABLE (OUT)
NEGATIVE
+5V SUPPLY
CONT/STORE (IN) (HANDSET)
NOT USED
VALUE
FUNCTION
NOT USED
SERIAL RECEIVE
SERIAL TRANSMIT
6
6
8
14
15
21
22
23
PUMP
PUMP "Y" PLUG
September 2004
Page 19

Advertisement