DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Both the forward and reverse
-09
directional switches are closed at the
same time.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
POSSIBLE CAUSE
for
Forward or reverse directional switch welded
Traction
closed or mis-adjusted to be held closed.
• Replace or adjust directional switches to
Controller
insure that they open when directional switch
is returned to neutral.
Short circuit between battery positive and P4
and/or P5.
• Disconnect wires from P4 and P5 and check
wire for short circuit to positive side of
directional switch.
Defective Control
• Disconnect wires and measure voltage at P4
and P5. Voltage should be less than 60% of
battery volts.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Start switch closed on power up after
-11
initial key switch closure.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
POSSIBLE CAUSE
for
Start switch input mis-adjusted or defective.
Traction
• Input voltage at P3 should be less than 60% of
Controller
battery volts at key switch closing. Adjust or
replace accelerator unit to insure that the
voltage at P3 is less than 60% of battery volts
before closing the start switch.
Short circuit between battery positive and P3 in
start switch input circuit.
• Disconnect wire from P3. Check for short
circuit from this wire to battery positive.
Defective control.
• Disconnect wire from P3. Measure voltage
from P3 to negative. Voltage should be zero, if
not, replace control.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when P4 and P5
are greater than 60% of battery volts at the same
time.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
L
P1
P17
P2
P6
CAUSE OF STATUS INDICATION
This status code will be displayed when P3 is greater
than 60% of battery voltage when the key switch is
closed.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
L
P1
P17
P2
P6
Page 28
P8
P3
P4
P5
P9
P7
ACCPOT
P8
P3
P4
P5
P9
P7
ACCPOT
September 2004