6. APPLICATION NOTES

6.1

GENERALIZED DATA LINK TESTING

CONVOLUTIONAL ENCODER
MODULATOR
UP CONVERTER
The block diagram above illustrates a typical telemetry uplink and receive station loopback test configuration involving
several types of equipment. Testing of these devices can benefit from using more than a simple bit error rate tester. This
note identifies several unique requirements that the AL6300 Data Link Test Set addresses.
"I" & "Q" CHANNELS
6.1.1
Multiple DLTM4 modules may be housed in a single AL6300 DLTS chassis. Two channels are used to test independent
"I" & "Q" channels in a QPSK data link. Operation at the same rate can be achieved by slaving one DLTM4 module
transmitter to the other using the external clock input (ST). Therefore two independent data streams can be generated with
a matched clock phase and frequency. The two channels can alternately be operated at different rates in an unbalanced
QPSK data link.
6.1.2

ERROR SIMULATIONS

The DLTM4 Transmitter provides a number of useful error insertion tools. These errors are inserted after the PRN or
PCM data is generated and before the IRIG bit-code converter.
6.1.2.1 Insert One Error
The first error type is the inversion of a single bit per command. This command provides a quick way to verify that the
DLTM4 receiver, which is showing ZERO errors, is actually connected and properly functioning when it detects and
displays the single error.
A
L
, I
.
POGEE
ABS
NC
Table 12: Total Instruction Set
Returned Value / Comments
The PCM Value field sets the value that is to be set or read into/from the
value defined in the PC## field. Reading or editing a PCM field is a two-
step process. First set the PC## to select which command to read/edit,
then read/set the PV## to read/edit the value.
TX

Figure 19: Typical Telemetry Data Link Block Diagram

09.21.2017
RX
DATA
LINK
TEST
SET
ANT/PICK OFF
TELEMETRY SYSTEM
OVERVIEW TEST
21
210 South 3
MODEL 2349 DLTM4
Found in
Sub-Menu
Figure 15
VITERBI DECODER