Changing Internal Jumper Link Positions (receiver only)
1. Remove the receiver power supply module from the light curtain housing.
2. Observe and note the position of the jumper links (see Electrical Connections chapter).
3. To reconfigure the factory settings of a new FF-SB Series light curtain to the cycle start mode, carefully
remove the jumper links and plug them in the positions illustrated in figure 4-13.
4. Perform an operational test to ensure proper functional readiness.
Figure 4-11 Factory Setting Jumper Link Positions on Receiver Power Supply Board