Install pin into connector as follows:
1. Strip about 8 mm (0.3 inch) of insulation from the wire end.
2. Using a crimping tool, crimp the pin onto the wire.
3. Push the pin into the correct slot in the connector. Tabs on the sides of the pin will expand into slots and
hold the pin in place when properly seated.
Remove a pin from the connector as follows:
1. Remove the gray plastic receptacle from the plug.
2. Remove the ground screw.
3. Using a screwdriver, pry up the edges of the plastic retainer piece on each side of the receptacle.
4. Slide the plastic retainer up and remove it.
5. Slide the metal part on each side down, and remove it.
6. Using a screw driver in the side slots, push the top part off.
7. Using the removal tool equivalent to FF-SBZREMOV (Honeywell part number FF-SBZREMOV), slide
over pin and push until the spring releases the pin; remove pin.

Power Wiring

FF-SB Series light curtains operate on either 120 or 240 volts ac. The emitter and receiver units
automatically switch to the ac voltage applied with the exception of FF-SB12E/R02E-S2 which operates on
120 Vac only.
A low voltage version (24-48 Vdc) is available for the FF-SB14 and FF-SB15 Series.
All of the FF-SB Series light curtains have the same connections for power. Figure 3-2 shows the power
connections. Figure 3-3 illustrates the receiver connections.
Figure 3-2 Emitter and Receiver Power Connections
Note : For Vdc versions, the supply connection is the following :
Terminal A4 :
Terminal A5 :
However, the FF-SB14 and FF-SB15 low voltage light curtains are polarity independent.
50
Supply Voltage
Neutral
Earth Ground
+
-
107062-12 EN FR26 GLO 501 Printed in France