COLORado ™ Service Maintenance Guide
Symptom(s)
1 or more LED's are not illuminating
1 or more LED's are producing very low
output
Breaker/Fuse keeps blowing
Device has no power
Fixture is not responding to DMX
Loss of signal
COLOR-CON Controller does not
function, or does not function properly
Stand alone operation
Display reading: "warning heat"
COLORado™6 User Manual
Clean the fixture regularly to avoid any such failure. This fixture is
convection cooled, which means that if the surface is kept clean and free
of debris, then proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event, all of
the red, green, or blue in a single module will no longer illuminate. This
does not mean that all of the LEDs have failed, but the circuit is wired in
series.
An LED may have failed, resulting in an short circuit. In this event, only
the single LED which has failed will no longer function.
-Note: In the event of LED failure, a replacement LED PCB assembly
may be purchased directly from Chauvet
Check that the lens assembly is installed properly. If the lens assembly is
not aligned properly over the LEDs, then they will not project fully
-See section on Lens Assembly Installation
-Note: In the event of LED failure, a replacement LED PCB assembly
may be purchased directly from Chauvet
Check total load placed on the electrical circuit
Check for a short in the electrical wiring: internal and/or external
Check device's fuse (internal)
Check for power on Mains
Check cable connections The COLORado™ IP68 cables must be firmly
connected for operation
Check for manual power off from the display by pressing and holding
down the {EXIT} button for more than 3 seconds
-Note: In the event of autoswitching transformer failure, the unit can be
sent in for repair; however, a replacement part can be ordered directly
from Chauvet
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections The COLORado™ IP68 cables must be firmly
connected for operation
Call service technician
-Note: In the event of Master PCB failure, a replacement PCB can be
ordered directly from Chauvet
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables or black lights
Make sure connector is firmly connected to device
The COLORado™ fixture must be in the correct mode in order to
properly respond to the COLOR-CON controller. The correct mode is
"CON" under "RUN" in the onboard Control Panel
This fixture has built-in, automatic programs that may be triggered from
the onboard Control Panel
The COLORado™6 features a thermal protection that will be
implemented in the event of over-heating. This can occur if the fixture in
not in an ideal location for the convection cooling to be effective
34
Possible Solution(s)
Part#: P222-C1LEDPC
Part#: P222-C1LEDPC
Part#: P170-C6MPCB
Part#: P140-C6ELTR
1/15/2008 11:12 AM