Vision tools 09V0002B Technical Manual page 20

Table of Contents

Advertisement

PSS/RPSS Switches the outputs PSS1...2 on
Write:
PSS1<STATUS>
_PSS1<STATUS>
PSS1<0..1>
PSS2<x>
Read:
RPSS1
RPSS2
TRG Software trigger for Outputs OUT1...4
Write:
TRG1<TIME>
_TRG1<TIME>
TRG1<0...9999>
TRG2<xxxx>
TRG3<xxxx>
TRG4<xxxx>
If TRG1..4 is sent with empty brackets "<>", the time of TMR1..4 is taken.
Technisches Handbuch
Version 5.2
Answer: none
Answer: „ACK"
0 = Switches PSS1 off
1 = Switches PSS1 on
Switches at X3.1 24Volt on/off. Used to supply voltage to a connected
sensor with max. 200mA.
see PSS1<x>
Switches at X4.1 24Volt on/off. Used to supply voltage to a connected
sensor with max. 200mA.
Answer: PSS1<0..1>
Answer: PSS2<0..1>
Answer: none
Answer: „ACK"
0..9999 ms Duty cycle for OUT1
with CFO1<0,xxxx> Output OUT1.24 is switched on and the PWM signal
at Output OUT1.PWM is output. After the time has elapsed, both outputs
are switched off.
with CFO1<1,xxxx> the PWM signal is output at Output OUT1.24. After
the time has elapsed, the output is switched off.
see TRG1<xxxx>
see TRG1<xxxx>
see TRG1<xxxx>
Technical data