Vision tools MDL600 Technical Manual

Vision tools MDL600 Technical Manual

Led module light white-diffuse

Advertisement

Quick Links

Technical Manual
MDL600 LED module light white-diffuse
Article-No.: 08K0008A
Version: 1.5

Advertisement

Table of Contents
loading

Summary of Contents for Vision tools MDL600

  • Page 1 Technical Manual MDL600 LED module light white-diffuse Article-No.: 08K0008A Version: 1.5...
  • Page 2 © Vision Tools Bildanalyse Systeme GmbH Heinrich-Hertz-Straße 7 68753 Waghäusel Germany Tel.: +49 7254 – 9351 0 Fax: +49 7254 – 9351 200 www.vision-tools.com info@vision-tools.com Revision date: April 2019 Version: Version change: Attachment, Technical data...
  • Page 3: Table Of Contents

    Table of contents Table of contents Table of contents ..............1 General ..................2 Abbreviations ....................2 Information on the manual ................2 Documents enclosed ..................2 Safety information ................... 2 Limitation of liability ..................4 Copyright law ....................4 Guarantee and Liability ...................
  • Page 4: General

    General General Abbreviations The abbreviations used are explained below:  V60 = image analysis program from the VisionTools company  PPE = personal protective equipment  I/O = input/output  MDL = module light Information on the manual This technical manual contains important instructions for working with the product named on the cover sheet.
  • Page 5 General Note General information Follow the instructions In accordance with DIN EN ISO 7010 General warning sign In accordance with DIN EN ISO 7010 Warning of electrical voltage In accordance with DIN EN ISO 7010 Warning of hot surface In accordance with DIN EN ISO 7010 Warning of oxidising substances In accordance with DIN EN ISO 7010 Technical Manual...
  • Page 6: Limitation Of Liability

    General Limitation of liability All information and statements in this manual are compiled in consideration of valid standards and regulations, as well as state of the art technological knowledge. The manufacturer accepts no liability for damages due to:  Failure to observe this manual ...
  • Page 7: Safety

    Safety Safety Appropriate use The best possible contrast is needed for various tests with V60. In order to produce a good contrast, the desired location is illuminated by one or more MDLs. Foreseeable misuse Any other use besides that determined in Appropriate use this chapter or any use extending beyond this is not appropriate! The operator will bear sole responsibility ...
  • Page 8: Technical Data

    Technical Data Technical Data Designation Min. Typ. Max. Unit Type of glass diffuse Wavelength 5500 (White) Number LEDs Lumen per LED Lumen Typ. 3888 Operating voltage Operating current 1,76 2,16 2,32 Power consumption 0 – 10 Dimming external 0 – 100 Dimming internal Dimming fix 10 –...
  • Page 9: Dimensions (Mm)

    Technical Data Dimensions (mm) X = 620 Pin Assignment Signal Colour of Conductor +24 VDC brown — white 0 V (GND) blue black M12 Male-Connector 4pin A-Coded Settings Switch Position Setting (MODE) internal dimming (Poti) luminosity fix external control Technical Manual Version 1.5...
  • Page 10: Commissioning

    Commissioning Commissioning Initial operation Specifically, the following points should be noted:  The specified operating voltage of the MDL (The operating voltage can be found in chapter Technical Data)  The MDL glows continuously because the slider is in the delivery status is at the second position.
  • Page 11: Assembly

    Commissioning Assembly On the back of the MDL, either a flange clamping piece (for mounting to round tubes 18x1.5mm) or an aluminium joint (for mounting on item profiles) can be mounted with the help of slot nuts. In order to rotate an MDL with a flange clamping piece by 90°, it is advisable to install a dedicated adapter plate between the MDL and the flange clamping piece.
  • Page 12: Maintenance And Repair

    The frequency of such checks depends on the cleanliness of the environment. Recommended Spare Parts Article-no. Product 08K0903I replacement lens MDL600 diffuse 10B0006A Alu-joint 8 40x40 10A0008A Flange clamp FK 18 10A0008B Flange clamp FK 18 with elongated hole 08K0101A Adapter plate 90°...
  • Page 13: Disposal

    Disposal Disposal Dispose special waste and garbage according to internal provisions and regulations. These must be brought to the correct collection stations. Your responsible administrative authority can give you more specific information on where authorized collection stations can be found. NOTE! Observe national regulations and internal operational solutions! Dispose of the packaging of production materials (including in the product cycle of the...
  • Page 14: Notes

    Notes Notes Technical Manual Version 1.5...
  • Page 15: Attachment

    Attachment Attachment 10.1 Declaration of conformity Konformitätserklaerung Technical Manual Version 1.5...

This manual is also suitable for:

08k0008a

Table of Contents