Configure CIP/RCIP IP addresses
Write:
CIP<IPAddr,Mask,Gateway,DNS1,DNS2,HostName>
_CIP<IPAddr,Mask,Gateway,DNS1,DNS2,HostName>
E.g. CIP<192.168.0.10,255.255.255.0,192.168.0.1,0.0.0.0,VOE_HOST>
Read:
RCIP
E.g.: CIP<00:04:A3:D0:00:00,192.168.0.10,255.255.255.0,192.168.0.1,0.0.0.0,VOE_HOST>
RVER Returns the program version
Read:
RVER
UPL Upload Mode
Send:
UPL
The controller is set to upload mode for 4 seconds. See Bootloader.
TEST starts and stops the test run.
Send:
TEST
The controller is set to test mode.
CADC Calibration of the analogue measurement
Send:
CADC
See Calibration of analogue measurement.
Technisches Handbuch
Version 5.2
Answer: CIP<MACAddr,IPAddr,Mask,Gateway,DNS1,DNS2,HostName>
Answer: VER<vX.XX.XX>
Answer: UPL<vX.XX.XX>
Answer: TEST<1>
Answer: TEST<0>
Answer: RVER<vX.XX.XX>
Technical data
Answer: none
Answer: „ACK"