OUT/ROUT Switches the outputs OUT1...4
Write:
OUTx<STATUS>
_OUTx<STATUS>
OUT1<0..1>
OUT2<x>
OUT3<x>
OUT4<x>
Read:
ROUT1
ROUT2
ROUT3
ROUT4
OUTP Switches the outputs OUT1...4 with PWM value
Write:
OUTPx<STATUS,PWM>
_OUTPx<STATUS,PWM>
OUTP1<0..1,0..100>
OUTP1<0..1,0..100>
Technisches Handbuch
Version 5.2
Answer: none
Answer: „ACK"
0 = Switches OUT1 off
with CFO1<0,xxxx> Output OUT1.24 is switched off and the PWM signal
at output OUT1.PWM is stopped.
with CFO1<1,xxxx> the PWM signal is stopped at Output OUT1.24.
1 = Switches OUT1 on
with CFO1<0,xxxx> Output OUT1.24 is switched on and the PWM signal
at Output OUT1.PWM is output.
with CFO1<1,xxxx> the PWM signal is output at Output OUT1.24.
see OUT1<x>
see OUT1<x>
see OUT1<x>
Answer: OUT1<0..1>
Answer: OUT2<0..1>
Answer: OUT3<0..1>
Answer: OUT4<0..1>
Answer: none
Answer: „ACK"
0 = Switches OUT1 off
with CFO1<0,xxxx> Output OUT1.24 is switched off and the PWM
signal at output OUT1.PWM is stopped.
with CFO1<1,xxxx> the PWM signal is stopped at Output OUT1.24.
1 = Switches OUT1 on
with CFO1<0,xxxx> Output OUT1.24 is switched on and the PWM
signal at Output OUT1.PWM is output.
with CFO1<1,xxxx> the PWM signal is output at Output OUT1.24.
0..100% Brightness for OUT1.
Technical data