Installation - Simu DMI5 Hz Series Original Instructions Manual

Hide thumbs Also See for DMI5 Hz Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
These instructions apply to all DMI5 Hz/DMI6 Hz drive, the different versions of which are available in the current catalogue.
Field of application: DMI5 Hz/DMI6 Hz drive are designed to drive all types of roller shutters, outdoor awnings without cassette. The
installer, who must be a motorisation and home automation professional, must ensure that the drive product is installed in accordance with
the standards in force in the country in which it is installed such as EN 13659 relating to roller shutters, and EN13561 relating to outdoor
screens and awnings.
Liability: Before installing and using the drive, please read operating and installation guide carefully. Please read these instruc-
tions carefully before installing and using the drive. In addition to following the instructions given in this guide, the instructions detailed in
the attached Safety instructions document must also be observed. The drive must be installed by a motorisation and home automation
professional, according to instructions from SIMU and the regulations applicable in the country in which it is commissioned. It is prohibited
to use the drive outside the field of application described above. Such use, and any failure to comply with the instructions given in this
guide and in the attached Safety instructions document, absolves SIMU of any liability and invalidates the warranty. The installer must
inform its customers of the operating and maintenance conditions for the drive and must provide them with the instructions for use and
maintenance, and the attached Safety instructions document, after installing the drive. Any After-Sales Service operation on the drive
must be performed by a motorisation and home automation professional. If in doubt when installing the drive, or to obtain additional infor-
mation, contact a SIMU adviser or go to the website www.simu.com.

Installation

1
Instructions which must be followed by the drive and home automation professional installing the drive:
- Methods of wiring are given by national standards or IEC 60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- The cable for the motor cannot be removed. If it is damaged, return the drive to the After-Sales department.
Recommendations: Keep a minimum distance of 20 cm between two DMI Hz motors. Keep a minimum distance of 30 cm
between DMI Hz motors and Hz transmitters. A radio appliance using the same frequency (433,42 MHz) may deteriorate our
product's performance (ex.: hi-fi radio headphones).
Drilling the tube:
A
C
D
A
DMI5 Hz
• 25/17
10/17
• 50/12
35/17
230V ~ 50Hz
DMI6 Hz
• 80/12
60/12
• 120/12
100/12
230V ~ 50Hz
Mounting:
1/5
DMI5 Hz / DMI6 Hz
(230V~50Hz)
4 x ØB / 90°
Ø4,8 x 10
Ø min.
4 x ØB / 90°
T min.
Ø / T min. A
B C D
716
26 4,2
47
756
-
-
5
36
8
60
836
-
-
4
1
STEEL
2
Nm ≥ 60 & ALUMINIUM WHEEL
EN- ORIGINAL INSTRUCTIONS
5008554I
S.A.S. au capital de 5 000 000 € - Z.I. Les Giranaux
BP71 - 70103 Arc-Les-Gray CEDEX
RCS GRAY B 425 650 090 - SIRET 425 650 090 00011
n° T.V.A CEE FR 87 425 650 090
i
7 mm
+
6 mm
92
41,7
3
DMI5 Hz : 9910004
DMI6 Hz : 9910062
-20°C / +60°C
4 x 90°
Ø12 x 20
4 x Ø 6,4 / Ø86
92

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmi6 hz seriesSmdmi510hzSmdmi525hzSmdmi535hzSmdmi550hz

Table of Contents