Explosion-Protection Approvals

The explosion-protection approvals are valid for use of the device in gas/vapour-air mixtures of combustible gases and vapours
under atmospheric conditions. The explosion-protection approvals are not valid for use in oxygen-enriched atmospheres. Unau-
thorised opening of the enclosure invalidates the explosion-protection approval.
— ATEX
— IECEx
— UL
(Underwriters Laboratories Inc.)
— CSA
1)
The year of manufacture is indicated by the third letter of the serial number on the type plate: T = 2003, U = 2004, W = 2005,
X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, etc.
example: serial number ARUH-0054, the third letter is U, so the year of manufacture is 2004.
The appendix has a copy of the ATEX certificate, which offers relevant information on safety regulations under subjects such as
"Subject matter and type", "Description", "Characteristic quantity" and "Terms/conditions of safe use".
Type IDS 0001
II 2G EEx d IIC T6
o
II 2D IP6X T80
C
o
C ≤ Ta ≤ +65
o
–40
C
Type IITR 001X
II 2G EEx d IIC T6
o
II 2D IP6X T80
C
o
C ≤ Ta ≤ +60
o
–40
C
Types IDS 0011 and ITR 000x:
II 2G EEx de IIC T6
o
II 2D IP6X T80
C
o
o
C ≤ Ta ≤ +65
–40
C
year of construction (by serial number)
BVS 05 ATEX E 143X
Type IDS 0001:
Ex d IIC T6, DIP A21 IP6X T80
o
o
C ≤ Ta ≤ +65
–40
C
Types IDS 0011 and ITR 000x:
Ex de IIC T6, DIP A21 IP6X T80
o
C ≤ Ta ≤ +65
o
–40
C
BVS 05.0011X
Type IDS 0001:
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Type IDS 0001:
Class I, Div. 1, Groups A, B, C, D
C22.2, No. 152
0158
0158
0158
1)
o
C
o
C
Explosion-Protection Approvals
C
US
®
LR97594