Download Print this page

Gabarron Elnur A-4 Installation Instructions And User Manual page 3

Industrial heater

Advertisement

kW
kcal/h
A-4
4
3.456
Single phase
A-4
4
3.456
A-6
6
5.184
A-9
9
7.776
A-12
12
10.368
WIRING 3x400V~+N (MODELS A-4, A-6, A-9 and A-12)
The symbol on the product or in its packaging indicates that this product may not be treated as
household waste. Instead it shall be handed over to the applicable collection point for the recycling of
electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human health, which could otherwise
be caused by inappropriate waste handling of this product. For more detailed information about
recycling of this product, please contact your local city office, your household waste disposal service or
the shop where you purchased the product. These instructions are only valid in the EU member states.
Industrial Heater
TECHNICAL SPECIFICATIONS
Tensión
3
m
/h
Voltage
230V~
400
400V~3N
400
400V~3N
600
400V~3N
750
400V~3N
900
WIRING 230V~ (MODEL A-4)
3
ancho
fondo
width
depth
height
37cm
27cm
38cm
37cm
27cm
38cm
43cm
27cm
43cm
43cm
37cm
46cm
43cm
37cm
46cm
L
Phase
N
Neutral
PE
Earth
C1
Contactor
I1
Fan only switch
I2
Heating switch
T
Control thermostat
TR
Delay thermostat
TS
Safety limiter
M
Fan
R1, R2, R3 heating elements
L
Phase
N
Neutral
PE
Earth
C1
Contactor
I1
Fan only switch
I2
Heating switch
T
Control thermostat
TR
Delay thermostat
TS
Safety limiter
M
Fan
R1, R2, R3 heating elements
alto
kg
10
10
11
16
17

Advertisement

loading

This manual is also suitable for:

Elnur a-6Elnur a-9Elnur a-12