Bosch KTS 515 Product Description page 17

On-board diagnosis
Hide thumbs Also See for KTS 515:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
3.3
Scope of delivery
Designation
System tester KTS 515
Bluetooth USB adapter
1)
OBD diagnostic cable 1.5 m
USB connecting cable 3 m
1)
Power supply unit
Power cord
Software package
1)
Case
1)
Mount
1)
with self-tapping screw (2x)
and oval head screw (3x)
Important information and safety instructions
Product description
not included in delivery of BEA 750
1)
3.4
Special accessories
Information on special accessories can be obtained
from authorized Bosch dealers.
3.5
System tester
3.5.1
Diagnosis panel
max. 60V
CH1
3
1
2
Fig. 1:
Diagnosis panel
1 No function
2 No function
3 No function
4 OBD diagnostic cable connection (DIAG)
3.5.2
Connection panel
15V DC
1
Fig. 2:
Connection panel
1 Power supply unit connection
2 LED A and LED B (refer to Section 3.5.3)
3 USB connection
Robert Bosch GmbH
Order number
1 687 023 449
1 684 465 555
1 684 465 562
1 687 023 620
1 684 461 106
1 687 005 086
1 685 438 626
1 681 398 030
2 910 611 405
2 910 641 118
1 689 979 922
1 689 989 036
DIAG
459802/14 Ko
4
USB
A B
459802/11 Ko
2
3
Description of unit | KTS 515 | 17
3.5.3
Functions of LEDs A and B
Status
LED A
KTS 515 ready for op-
Does not illumi-
eration
nate
Data communication
Flashes green
with the controller
(irregular)
Firmware update
Does not illumi-
in operation
nate
LED A
Function
Does not illumi-
No data communi-
nate
cation with the con-
troller
Flashes green
Data communication
(irregular)
with the controller
Illuminated green
Fault in hardware/
Firmware
Illuminated red
Power supply
> 35 Volt.
LED B
Function
Does not illumi-
Voltage not present
nate
Flashes green
KTS 515 ready for op-
(1 second inter-
eration
val)
Illuminated green
Fault in hardware/
Firmware
Flashes yellow
Overvoltage on
(1 second inter-
diagnostic cable
val)
Illuminated yellow Fault in hardware/
Firmware
Flashes red
Firmware update
(irregular)
in operation
Illuminated red
Fault in firmware-
update
Unplug the USB connection and power supply and connect them
*)
again. If the error still exists, contact customer service.
3.5.4
Adapter insert (IBOX 01)
The adapter insert (fig. 3, item 4) contains all of the
existing capabilities for establishing communication
with the vehicle diagnosis interfaces that are known. In
order to flexibly adapt to future expansions in diagnosis
protocols, the adapter insert can be changed quickly
without any tools.
i
KTS modules only function with the adapter insert
connected.
en
LED B
Flashes green
(1 second interval)
Flashes green
(1 second interval)
Flashes red
(irregular)
Measures
Check connection
with the controller
None
*)
Check voltage in ve-
hicle
Measures
Check power
supply
None
*)
*)
*)
None
Repeat firmware
update
|
|
1 689 989 036