Batteries should always be charged as
required in order to have a long service life.
We advise you to use the circuit breaker
next to the battery tray to preserve the
service life of the battery when the vehicle
is not going to be used for a long time.
Check the battery voltage level if the
vehicle is parked for a long period of time.
12.2 V voltage level measured in a battery
indicates that battery charge level is too
low.
In this case, best method is to leave the
vehicle running in the shortest possible
time in order to charge the batteries.
MAINTENANCE AND SERVICE
Disconnecting the battery terminals
Disconnect the terminals aft er 5 minutes
minimum when you stop the engine. This
is needed to supply power to the Urea
system that will operate aft er a while
when the engine is stopped.
Otherwise, your Urea system (or vehicle)
may be damaged.
• Remove the key from the ignition switch.
• Turn off all consumers.
• Open the battery housing cover and
remove it.
• Disconnect the negative terminals.
• Disconnect the positive terminals.
- 193 -
Electrical Systems
WARNING
Risk of short circuit occurs when
the positive terminal of the battery
connected contacts the components of
the vehicle. Thus, the gas mixture that
may easily explode may ignite. You and
other persons may get injured in such a
condition. Do not place metal objects or
tools on the battery.
Disconnect the negative terminal fi rst,
and then the positive terminal while
disconnecting the terminals.
Connect the positive terminal fi rst,
and the negative terminal then while
connecting the terminals.
Do not loosen or disconnect the
terminals when the engine is running.
BATTERIES REQUIRE MAINTENANCE