Spray Height Controller Case 44 Series Main Lift Option Installation Manual (4-bolt) Improving the competitiveness of Industry and Agriculture through Precision Measurement...
Page 2
Reorder P/N: UC4+CS4-4B-INST Rev B (Case 44 Series Main Lift Kit – 44962D) NOTICE NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information...
TABLE OF CONTENTS INTRODUCTION ..........................1 PARTS LISTS ............................3 HYDRAULIC INSTALLATION ......................6 MAIN LIFT VALVE INSTALLATION ....................8 ELECTRICAL INSTALLATION ......................9 COMPLETING THE INSTALLATION ..................... 10 ...
Page 4
INTRODUCTION Congratulations on your purchase of the NORAC UC4+ Spray Height Controller. This system is manufactured with top quality components and is engineered using the latest technology to provide operating features and reliability unmatched for years to come. When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
CABLE VALVE CS4 INTERFACE 44865-48 HYDRAULICS FITTING KIT - CS4 44863-38 HOSE ASSEMBLY 122R2-06 156 IN L 6FORX 6FORX90 UC4+CS4-4B-INST MANUAL INSTALLATION UC4+ CASE 44 SERIES MAIN LIFT KIT - 44962D 44962D VALVE ASSEMBLY EXPANSION DPOC PROP DT 4 BOLT...
Page 6
FACE P - PIPE The use of dielectric grease is not recommended on any NORAC electrical connections. To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Permatex...
HYDRAULIC INSTALLATION 2. Install the 6MB 6MOR fitting (F04) into WARNING! the A and B ports of the expansion block (Figure 2). The hydraulic system creates very high pressure. Before disconnecting any hydraulic lines ensure all pressure has been bled from the system. IMPORTANT: Component failure...
Page 9
Route the free lift tee end of the hoses (H02) to the Case 13. Connect the NORAC hose (H02) that main lift tee, which is located near the is connected to the A port on the sprayer axle.
MAIN LIFT VALVE INSTALLATION If the sprayer was built prior to model year 3. Loosen the hoses on each side of one of 2007 then the main lift valve may have to be the main lift cylinders located at the replaced with a part from your local Case back of the sprayer.
ELECTRICAL INSTALLATION Figure 6 – Cable Connections 5. Connect the 2-pin connector on cable Cable C16 and C17 are the only C16 marked ROLL CCW to the coil cables included in the kit. on the port side of the valve block. 1.
COMPLETING THE INSTALLATION You can now continue to install the remainder of your UC4+ Spray Height Control System. If the system is fully installed then refer to the UC4+ Operators Manual to run an Automatic Install with the CS4 type selected.
7.2 I C17: 44658-62 - C CS4 I ABLE ALVE NTERFACE...