b). MOUNTING FACE: Mount thousandths
indicator as shown and rotate coupling.
VARIATION MUST NOT EXCEED .003"
MAXIMUM.
2. Check for gear backlash as follows:
A.E.R. MODELS (without idler gear): Mount
thousandths dial indicator on top of housing
so that arm extends through top inspection
hose and tip rests on the side of a pinion
tooth. Hold output coupling stationary and
gently twist pinion back and forth. The play
or 'backlash' must be between .004" and
.008".
3. Check for gear tooth contact:
If a NEW pinion and or idler gear are
installed check for tooth contact with
marking compound. Models without idler
gear, apply compound to pinion. Units with
idler gear apply compound to idler gear.

7.11 ADDITIONAL ASSEMBLY

1. Install inspection covers and gaskets
2. Install oil breather and dipstick
3. Install oil drain plug
4. Install gasket and baseplate
5. Install gasket and selector valve on
baseplate
6. Connect hose from selector valve tee to
oil pump.