D. ASSEMBLY
NOTE:
On all fittings use Permatex 'super 300' sealant,
graphite paste, or equivalent. CAUTION: Do not use
No.1 Permatex or Teflon tape.
1. If necessary install new seal in
cover. Press seal in until it bottoms
in bore (rubber face out). Apply
lubricant to seal.
2. Insert rotor shaft through oil seal in
cover
3. Set key in rotor shaft and install
lever with indexing ball and spring.
Make sure that keyway in rotor shaft
remains toward bottom of cover.
4. Tap control lever into position with a
soft hammer and secure with
retaining ring.
5. Position new cover gasket, on pilot
face of cover
6. Install rotor with cover into selector
valve body. Secure cover with four
capscrews. Tighten to 4 pounds-foot
torque.
7. Install safety relief adjustment parts
in rear of valve body.
8. Check for correct assembly by
moving lever back and forth.
Selector valve is now ready to be
installed on main housing. See
fig.19.