1. Switch off the power to the unit, and wait for the display to
switch off.
2. Press and hold [Status], [Main Menu] and OK at the same time
while switching on the power to the unit. The fan starts after
approximately 5 seconds or when you hear an audible click.

10. Servicing the product

CAUTION
Electric shock
Minor or moderate personal injury
Before starting any work on the product, make sure
that the power supply has been switched off and that it
cannot be accidentally switched on.
Touching the electrical parts may be fatal, even after
CUE has been switched off.
Conduct a functional test every 12 months to detect any failure or
malfunction of the STO functionality.
To conduct the functional test, perform the following steps:
Remove the 24 V DC voltage supply at terminal 37.
Check if the operating panel displays the alarm Safe Stop A68.
Verify that the frequency converter trips the unit.
Verify that the motor is coasting and comes to a complete stop.
Verify that the motor cannot be started.
Reconnect the 24 V DC voltage supply to terminal 37.
Verify that the motor is not started automatically and restarts
only by giving a reset signal (via bus, Digital I/O or the RESET
button).