Thermostat Confi guration

Entering the Room Number

Enter the room number by changing the characters on the screen.
Available characters include digits 0-9 and letters A-F. To distinguish between two or
more thermostats in the same unit, enter as follows:
Thermostat 1: 00100
Thermostat 2: 0100A
Press the FAN button to advance to the next digit;
Press the UP and DOWN buttons to increase or decrease the value;
Press the F|C button to advance to the next menu.
Entering the room number correctly is crucial for proper operation of networked
thermostats.
22
Thermostat Confi guration
Confi guring the Equipment Settings
Enter the equipment code by changing the digits on the screen. Refer to the table
below.
Press the FAN button to advance to the next equipment setting.
Press the UP and DOWN buttons to increase or decrease the value;
Press the F|C button to advance to the next menu.
Setting #1
Setting #2
Digit
Compressor Type
Electric Heat
0
No Compressor
No Electric Heat
1
Heat Pump
Electic Heat*
2
Air Conditioner*
† Setting #3 can be ignored since the HVAC Controller has no outputs for reversing
valves.
*Indicates default setting.
Setting #3
Setting #4
Reversing Valve
Fan Speed
N/A
One Fan Speed*
Two Fan Speeds