3 - INFORMATION FOR SET UP
3.10

GENERAL PARAMETERS: DESCRIPTION

no. 89 Fair demo
0 - inactive
1 - active.
To activate this mode, it is necessary to
set parameter 35 at 1, parameter 6 (for
example) at 200 mm, and parameter 85
"Bar Change" at 1.
no. 90 Wrong bar feeder phase
0 - (K37 active with closed guide
channels in manual mode).
During the "MANUAL" cycle, the bar
feeder goes into "ALARM" when
performing movements (for example
"guide channel opening"). The bar feeder
"WORKING" phase is lost and must be re-
established; the "BAR FEEDER WAITING"
message will be displayed.
1 - (Bar feeder in manual mode and
lathe in automatic mode).
At the first bar feeding signal, the bar
feeder goes into "ALARM" mode if it is in
manual mode.
WARNING - CAUTION
After
"MANUAL/AUTOMATIC" lathe signal is given, this safety is not activated if the
bar feeder is working in "MANUAL" mode from the lathe.
89
DEFAULT VALUE
90
DEFAULT VALUE
the
3 - Pag. 25 / 26
KID 80 SIV
no. 89 Fair Demo
x
PROGRAMMABLE
K I D
0
no. 90 Wrong bar
feeder phase
xxxxxxxxxxx
PROGRAMMABLE
K I D
0
EN
VALUE
K I D
0/1
VALUE
K I D
0/1