Portwell COM Express PCOM-B700G User Manual

Portwell COM Express PCOM-B700G User Manual

Table of Contents

Advertisement

Quick Links

COM Express™
PORTWELL PCOM-B700G User's Guide
COM Express™
PCOM-B700G
User's Guide
R1.2
Copyright © PORTWELL 2018
PCOM-B700G User's Guide
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COM Express PCOM-B700G and is the answer not in the manual?

Questions and answers

Summary of Contents for Portwell COM Express PCOM-B700G

  • Page 1 COM Express™ PORTWELL PCOM-B700G User's Guide COM Express™ PCOM-B700G User's Guide R1.2 Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 2 COM Express™ PORTWELL PCOM-B700G User's Guide Revision History Rev. Note Date R1.0 Preliminary March.2018 R1.1 Update mechanical drawing June 2018 R1.2 Update BIOS Screen June 2018 Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 3: Table Of Contents

    COM Express™ PORTWELL PCOM-B700G User's Guide Contents 1 Introduction ........................................11 2 Block Diagram ........................................12 3 Specifications ........................................13 3.1 PCOM-B700G Processor list ................................14 3.2 Supported Operating Systems ................................17 3.3 Windows OS driver ....................................18 3.4 Electrical Characteristics ..................................19 3.5 Mechanical Dimensions ..................................
  • Page 4 COM Express™ PORTWELL PCOM-B700G User's Guide Console Redirection Settings ................................80 Legacy Console Redirection Settings ..............................81 PCI Subsystem Settings ..................................82 PCI Express Settings ....................................83 PCI Express GEN 2 Settings ................................. 84 PCI Hot-Plug Settings ..................................... 85 Network Stack Configuration ................................. 86 CSM Configuration ....................................
  • Page 5 COM Express™ PORTWELL PCOM-B700G User's Guide SOCKET RAPL Config ..................................107 Common Refcode Configuration ................................ 108 QPI Configuration ....................................109 QPI General Configuration .................................. 110 QPI Per Socket Configuration ................................111 CPU (0~3)....................................... 112 Memory Configuration ..................................113 Memory Topology ....................................114 Memory Thermal ....................................
  • Page 6 View Smbios Event Log ..................................155 6.8 Save & Exit ......................................156 7 System Resources ......................................157 8 BIOS Update ........................................158 9 PORTWELL Software Tool .................................... 166 10 Industry Specifications ....................................167 Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 7 COM Express™ PORTWELL PCOM-B700G User's Guide List of Tables Table 1 PCOM-B700GVG SPEC ..........................................13 Table 2 PCOM-B700G Processor list ........................................16 Table 3 Supported OS list ............................................. 17 Table 4 Windows OS driver list ..........................................18 Table 5 Electrical characteristics ......................................... 19 Table 6 Weight .................................................
  • Page 8 COM Express™ PORTWELL PCOM-B700G User's Guide List of Figures Figure 1 Block Diagram ............................................12 Figure 2 Power on sequence ..........................................20 Figure 4 Mechanical Dimensions - Top ......................................21 Figure 5 Mechanical Dimensions - Bottom ......................................22 Figure 6 Mechanical Dimensions - Assembly view ..................................23 Figure 8 Heat sink / cooler mechanical dimensions ..................................
  • Page 9 PORTWELL products, regardless of the legal theory on which the claim is based, and even if PORTWELL has been advised of the possibility of such damages.
  • Page 10 PORTWELL PCOM-B700G User's Guide Technical Support PORTWELL technicians and engineers are committed to providing the best possible technical support for our customers so that our products can be easily used and implemented. We request that you first visit our website at http://www.PORTWELL.com.tw/support/...
  • Page 11: Introduction

    1 Introduction The Portwell PCOM-B700G, a Type 7 COM Express basic (125mm x 95mm) module is designed with Intel® Xeon® processor D-1500 product family. Specifically, the COM Express 3.0 specification's Type 7 pinout, when compared to the Type 6 pinout, trades all the graphics interfaces for up to four 10GbE ports and a total of 32 PCIe lanes, ideal for applications in micro server and the like, requiring low power consumption while supporting high computing performance and communication throughput.
  • Page 12: Block Diagram

    COM Express™ PORTWELL PCOM-B700G User's Guide 2 Block Diagram Figure 1 Block Diagram Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 13: Specifications

    COM Express™ PORTWELL PCOM-B700G User's Guide 3 Specifications Table 1 PCOM-B700GVG SPEC *Note1 The PEG available lanes configurations are shown below: 1x16 (Default) 0 10 11 12 13 14 15 1x8 + 2x4 2x4 + 1x8 Copyright © PORTWELL 2018...
  • Page 14: Pcom-B700G Processor List

    COM Express™ PORTWELL PCOM-B700G User's Guide 3.1 PCOM-B700G Processor list PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G PCOM-B700G series D-1507 D1508 D1517 D1519 D1527 D1537 D1539 D1548 D1557 D1577 Ordering P/N AB1-3F51Z AB1-3F52Z AB1-3F53Z Intel® Intel® Intel®...
  • Page 15 COM Express™ PORTWELL PCOM-B700G User's Guide 1000Base-T 10GBase-T Operating Temperature -40°C to 85°C -40°C to 85°C Range Advanced Technologies Intel® Turbo Boost Technology Intel® Hyper-Threading Technology Intel® Virtualization Technology (VT-x) Intel® Virtualization Technology for Directed I/O (VT-d) Intel® VT-x with...
  • Page 16: Table 2 Pcom-B700G Processor List

    COM Express™ PORTWELL PCOM-B700G User's Guide Idle States Enhanced Intel SpeedStep® Technology Thermal Monitoring Technologies Intel® AES New Instructions Secure Key Trusted Execution Technology Execute Disable OS Guard Table 2 PCOM-B700G Processor list Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 17: Supported Operating Systems

    COM Express™ PORTWELL PCOM-B700G User's Guide 3.2 Supported Operating Systems The PCOM-B700GVG supports the following operating systems. Vendor Operating System Supported Microsoft Windows 7 (32/64bit) Windows 8 (32/64bit) Windows 8.1 (32/64bit) Windows 10 (32/64bit) Microsoft Windows 2008 R2 SP1 Microsoft Windows 2012...
  • Page 18: Windows Os Driver

    COM Express™ PORTWELL PCOM-B700G User's Guide 3.3 Windows OS driver Please download the drivers from Portwell download center website http://www.portwell.tw/support/download_center.php Drivers file name Supported Operating Systems 10GLAN_Win7_64 Windows Server 2008 R2 (64bit) Microsoft Windows 7 (64bit) Chipset_Win7_8_81_32_64 Microsoft Windows 7 (32/64bit) Microsoft Windows 8 (32/64bit) Microsoft Windows 8.1 (32/64bit)
  • Page 19: Electrical Characteristics

    COM Express™ PORTWELL PCOM-B700G User's Guide 3.4 Electrical Characteristics Input voltage +12VDC (Nominal) +6VDC ~ +19VDC (Wide range) RTC Battery Power on mode AT Mode Table 5 Electrical characteristics PCOM-B700GVG Power sequence Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 20 COM Express™ PORTWELL PCOM-B700G User's Guide Figure 2 Power on sequence Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 21: Mechanical Dimensions

    COM Express™ PORTWELL PCOM-B700G User's Guide 3.5 Mechanical Dimensions Figure 3 Mechanical Dimensions - Top Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 22 COM Express™ PORTWELL PCOM-B700G User's Guide Figure 4 Mechanical Dimensions - Bottom Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 23 COM Express™ PORTWELL PCOM-B700G User's Guide Figure 5 Mechanical Dimensions - Assembly view Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 24: Table 6 Weight

    COM Express™ PORTWELL PCOM-B700G User's Guide Net weight Module .0g +/- 2% Cooler (H/S+FAN) .0g +/- 2% Table 6 Weight Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 25: Sodimm Socket Design

    COM Express™ PORTWELL PCOM-B700G User's Guide 3.6 3 SODIMM socket design PCOM-B700G has designed additional Memory SODIMM socket at the bottom, which supports up to DDR4 48GB capacity. Before inserting the DDR4 SODIMM memory, please refer to below SODIMM arrangement and note that, there are 2 SODIMM socket of channel 0, the CH0 SODIMM1 (the bottom one) works only if CH0 SDDIMM0 (the top one) is inserted.
  • Page 26: Table 8 Ordering Guide - Pcom-B700G

    COM Express™ PORTWELL PCOM-B700G User's Guide PCOM-B700G-D1519 AB1-3G80 Available (Wide-Temp) PCOM-B700G-D1527 AB1-3F51 Available PCOM-B700G-D1537 AB1-3G81 Available PCOM-B700G-D1539 AB1-3F52 Available (Wide-Temp) PCOM-B700G-D1548 AB1-3F53 Available PCOM-B700G-D1559 AB1-3G82 Available (Wide-Temp) PCOM-B700G-D1577 AB1-3G83 Available Table 8 Ordering Guide - PCOM-B700G Accessory Accessory Ordering P/N...
  • Page 27: Heat Sink / Cooler

    COM Express™ PORTWELL PCOM-B700G User's Guide 4 Heat sink / Cooler Heat sink Dimensions Figure 6 Heat sink / cooler mechanical dimensions Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 28: H/S Assembly Guide

    COM Express™ PORTWELL PCOM-B700G User's Guide 4.1 H/S Assembly guide Please refer Figure 7 Mechanical Dimensions - Assembly view 4.2 Packaging Package Appearance Size Anti-Static bubble bag 180x135mm White Paper Box 210x151x40mm Shipping Box 595x300x195mm (10 pcs White paper box) Copyright ©...
  • Page 29: Signal Descriptions And Pin Out Tables

    COM Express™ PORTWELL PCOM-B700G User's Guide 5 Signal Descriptions and Pin out Tables Signal Tables Terminology Descriptions Input to the Module Output from the Module Bi-direction input / output signal Open Drain output CMOS Logic input or output. Input thresholds and output levels shall be 80% of supply rail for high side and 20% of the relevant supply rail for low side.
  • Page 30 COM Express™ PORTWELL PCOM-B700G User's Guide #Note : Reserved / Not connected pins are highlighted as gray color. Signal Description Type Power / Tolerance PU / PD Note GND(FIXED) GND(FIXED) Gigabit Ethernet Controller 0: GBE0_MDI3- Media Dependent Interface Analog 3.3V max Suspend...
  • Page 31 COM Express™ PORTWELL PCOM-B700G User's Guide Gigabit Ethernet Controller 0: GBE0_MDI1+ Media Dependent Interface Analog 3.3V max Suspend Differential Pairs GND(FIXED) GND(FIXED) Gigabit Ethernet Controller 0: GBE0_MDI0- Media Dependent Interface Analog 3.3V max Suspend Differential Pairs Gigabit Ethernet Controller 0:...
  • Page 32 COM Express™ PORTWELL PCOM-B700G User's Guide Serial ATA or SAS Channel 0 SATA0_RX- SATA AC coupled on Module receive differential pair. GND(FIXED) GND(FIXED) PCI Express Differential Transmit PCIE_TX15+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit PCIE_TX15- PCIE...
  • Page 33 COM Express™ PORTWELL PCOM-B700G User's Guide RSVD Reserved Pin Selection straps to determine the BIOS_DIS0# / BIOS boot device.The Carrier PU 10K CMOS ESPI_SAFS should only float these or pull them ohm to 3.3V low. Shared pin with ESPI_SAFS Active low output indicating that...
  • Page 34 COM Express™ PORTWELL PCOM-B700G User's Guide USB over-current sense, USB channels 2 and 3. A pull-up for this PU 10K USB_2_3_OC# line shallbe present on the Module. CMOS 3.3V Suspend / 3.3V ohm to Do not pull this line high on the...
  • Page 35 COM Express™ PORTWELL PCOM-B700G User's Guide Pairs General purpose input pins. Pulled PU 10k GPI0 CMOS 3.3V / 3.3V high internally on the Module. ohm to 3.3V PCI Express Differential Transmit PCIE_TX4+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit...
  • Page 36 COM Express™ PORTWELL PCOM-B700G User's Guide General purpose input pins. Pulled PU 10k GPI2 CMOS 3.3V / 3.3V high internally on the Module. ohm to 3.3V PCI Express Differential Transmit PCIE_TX0+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit...
  • Page 37 COM Express™ PORTWELL PCOM-B700G User's Guide Pairs NCSI Transmit Enable PD 270 NCSI_TX_EN (PD 10K on Carrier when NC-SI is 3.3V Suspend / 3.3V not used on Carrier) General purpose input pins. Pulled PU 10k GPI3 CMOS 3.3V / 3.3V high internally on the Module.
  • Page 38 COM Express™ PORTWELL PCOM-B700G User's Guide General purpose output pins. GPO0 Upon a hardware reset, these CMOS 3.3V / 3.3V outputs should be low. SPI_CLK Clock from Module to Carrier SPI CMOS 3.3V Suspend / 3.3V Data out from Module to Carrier...
  • Page 39 COM Express™ PORTWELL PCOM-B700G User's Guide LID button. Low active signal used PU 47K to A103 LID# by the ACPI operating system for a CMOS 3.3V Suspend / 12V 3VSB LID switch. Primary power input: +12V A104 VCC_12V +12V nominal.
  • Page 40 COM Express™ PORTWELL PCOM-B700G User's Guide LPC multiplexed address, LPC_AD1 / ESPI_IO_1 command and data bus / Shared CMOS 3.3V / 3.3V pin with ESPI IO LPC multiplexed address, LPC_AD2 / ESPI_IO_2 command and data bus / Shared CMOS 3.3V / 3.3V...
  • Page 41 COM Express™ PORTWELL PCOM-B700G User's Guide System Management Bus Alert – active low input can be used to PU 4.7k SMB_ALERT# generate an SMI# (System CMOS 3.3V Suspend / 3.3V ohm to Management Interrupt) or to wake 3VSB the system.
  • Page 42 COM Express™ PORTWELL PCOM-B700G User's Guide other configurable devices time to be programmed. PCI Express Differential Receive PCIE_RX14+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX14- PCIE AC coupled off Module Pairs Output indicating that a watchdog CMOS 3.3V / 3.3V...
  • Page 43 COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Receive PCIE_RX12+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX12- PCIE AC coupled off Module Pairs GND(FIXED) GND(FIXED) USB differential pairs, channels 3. USB3- All USB ports except USB7, if 3.3V Suspend / 3.3V...
  • Page 44 COM Express™ PORTWELL PCOM-B700G User's Guide This signal is used by the Carrier to indicate the operating mode of the LPC/eSPI bus. If pulled down by the Carrier LPC mode is selected. If pulled up or left ESPI_EN CMOS floating, eSPI is selected if available.
  • Page 45 COM Express™ PORTWELL PCOM-B700G User's Guide Reset output from Module to Carrier Board. Active low. Issued by Module chipset and mayresult from a low SYS_RESET#input, a PU 1k ohm CB_RESET# low PWR_OKinput, a CMOS 3.3V Suspend / 3.3V to 3VSB...
  • Page 46 COM Express™ PORTWELL PCOM-B700G User's Guide Pairs GND(FIXED) GND(FIXED) PCI Express Differential Receive PCIE_RX2+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX2- PCIE AC coupled off Module Pairs General purpose output pins. GPO3 Upon a hardware reset, these CMOS 3.3V / 3.3V...
  • Page 47 COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Receive PCIE_RX8- PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX9+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX9- PCIE AC coupled off Module Pairs PCI Express Differential Receive...
  • Page 48 COM Express™ PORTWELL PCOM-B700G User's Guide Selection straps to determine the BIOS_DIS1# / BIOS boot device.The Carrier PU 10k CMOS ESPI_BBS should only float these or pull them ohm to 3.3V low / Shared pin with ESPI_BBS NCSI_RX_ER NC-SI Receive error 3.3V Suspend / 3.3V...
  • Page 49 COM Express™ PORTWELL PCOM-B700G User's Guide Chip select for Carrier Board SPI - SPI_CS# maybe sourced from chipset SPI0 CMOS 3.3V Suspend / 3.3V or SPI1 PD 10k NCSI_ARB_IN NC-SI hardware arbitration input. 3.3V Suspend / 3.3V PU 10K to NCSI_ARB_OUT NC-SI hardware arbitration output.
  • Page 50 COM Express™ PORTWELL PCOM-B700G User's Guide Primary power input: +12V B109 VCC_12V +12V nominal. B110 GND(FIXED) GND(FIXED) GND(FIXED) GND(FIXED) Additional transmit signal USB_SSRX0- differential pairs for the PCIE AC coupled off Module SuperSpeed USB data path. Additional transmit signal USB_SSRX0+...
  • Page 51 COM Express™ PORTWELL PCOM-B700G User's Guide Additional transmit signal USB_SSRX3- differential pairs for the PCIE AC coupled off Module SuperSpeed USB data path. Additional transmit signal USB_SSRX3+ differential pairs for the PCIE AC coupled off Module SuperSpeed USB data path.
  • Page 52 COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Receive PCIE_RX6+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX6- PCIE AC coupled off Module Pairs GND(FIXED) GND(FIXED) PCI Express Differential Receive PCIE_RX7+ PCIE AC coupled off Module...
  • Page 53 COM Express™ PORTWELL PCOM-B700G User's Guide external Optical SFP Module I2C data signal of the 2-wire management interface used by the 10G_SFP_SDA2 10GbE controller to access the 3.3V Suspend / 3.3V management registers of an external Optical SFP Module Output signal that resets an optical...
  • Page 54 COM Express™ PORTWELL PCOM-B700G User's Guide external Optical SFP Module I2C data signal of the 2-wire management interface used by the PU 4.7K to 10G_SFP_SDA0 10GbE controller to access the 3.3V Suspend / 3.3V 3VSB management registers of an external Optical SFP Module Software-Definable Pins.
  • Page 55 COM Express™ PORTWELL PCOM-B700G User's Guide I/O interface mode clock signal for serial data transfers between the MAC and an external PHY. I2C Mode: I2C clock signal, of the 2-wire management interface used I/O OD 3.3V Suspend / 3.3V for serial data transfers between the MAC and an external PHY.
  • Page 56 COM Express™ PORTWELL PCOM-B700G User's Guide Pairs The TYPE pins indicate to the Carrier Board the Pin-out Type TYPE1# that is implemented on the Module. PCI Express Differential Receive PCIE_RX18+ PCIE AC coupled off Module Pairs PCI Express Differential Receive...
  • Page 57 COM Express™ PORTWELL PCOM-B700G User's Guide GND(FIXED) GND(FIXED) PCI Express Differential Receive PCIE_RX22+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX22- PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX23+ PCIE AC coupled off Module...
  • Page 58 COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Receive PCIE_RX27+ PCIE AC coupled off Module Pairs PCI Express Differential Receive PCIE_RX27- PCIE AC coupled off Module Pairs GND(FIXED) GND(FIXED) PCI Express Differential Receive PCIE_RX28+ PCIE AC coupled off Module...
  • Page 59 COM Express™ PORTWELL PCOM-B700G User's Guide Primary power input: +12V C104 VCC_12V +12V nominal. Primary power input: +12V C105 VCC_12V +12V nominal. Primary power input: +12V C106 VCC_12V +12V nominal. Primary power input: +12V C107 VCC_12V +12V nominal. Primary power input: +12V...
  • Page 60 COM Express™ PORTWELL PCOM-B700G User's Guide Additional transmit signal USB_SSTX1+ differential pairs for the PCIE AC coupled on Module SuperSpeed USB data path. Additional transmit signal USB_SSTX2- differential pairs for the PCIE AC coupled on Module SuperSpeed USB data path.
  • Page 61 COM Express™ PORTWELL PCOM-B700G User's Guide MDIO Mode: Management Data I/O interface mode data signal for 3.3V Suspend / 3.3V serial data transfers between the MAC and an external PHY. D16 10G_PHY_MDIO_SDA2 I2C Mode: I2C data signal, of the 2-wire management interface used I/O OD 3.3V Suspend / 3.3V...
  • Page 62 COM Express™ PORTWELL PCOM-B700G User's Guide 10GBASE-KR ports, transmit AC coupled on 10G_KR_TX3- output differential pairs. Carrier 10GBASE-KR ports, transmit AC coupled on 10G_KR_TX2+ output differential pairs. Carrier 10GBASE-KR ports, transmit AC coupled on 10G_KR_TX2- output differential pairs. Carrier GND(FIXED)
  • Page 63 COM Express™ PORTWELL PCOM-B700G User's Guide Phy mode select pin: If high Phy0 and Phy1 are configured by MDIO. If low Phy2 and Phy3 are 10G_PHY_SEL_01 configured by I2C. For MDIO 3.3V Suspend / 3.3V mode, this pin should be left not connected on the Carrier.
  • Page 64 COM Express™ PORTWELL PCOM-B700G User's Guide MDIO Mode: Management Data I/O interface mode data signal for 3.3V Suspend / 3.3V serial data transfers between the MAC and an external PHY. D45 10G_PHY_MDIO_SDA1 I2C Mode: I2C data signal, of the 2-wire management interface used I/O OD 3.3V Suspend / 3.3V...
  • Page 65 COM Express™ PORTWELL PCOM-B700G User's Guide Pairs PCI Express Differential Transmit PCIE_TX16- PCIE AC coupled on Module Pairs RSVD Reserved Pin PCI Express Differential Transmit PCIE_TX17+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit PCIE_TX17- PCIE AC coupled on Module...
  • Page 66 COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Transmit PCIE_TX21+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit PCIE_TX21- PCIE AC coupled on Module Pairs GND(FIXED) GND(FIXED) PCI Express Differential Transmit PCIE_TX22+ PCIE AC coupled on Module...
  • Page 67 COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Transmit PCIE_TX26+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit PCIE_TX26- PCIE AC coupled on Module Pairs PCI Express Differential Transmit PCIE_TX27+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit...
  • Page 68: Table 11 Pin Out Description

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Differential Transmit D101 PCIE_TX31+ PCIE AC coupled on Module Pairs PCI Express Differential Transmit D102 PCIE_TX31- PCIE AC coupled on Module Pairs D103 Primary power input: +12V D104 VCC_12V +12V nominal. Primary power input: +12V...
  • Page 69: Bios Setup Items

    COM Express™ PORTWELL PCOM-B700G User's Guide 6 BIOS Setup Items PCOM-B700GVG is equipped with the AMI BIOS stored in Flash ROM. These BIOS has a built-in Setup program that allows users to modify the basic system configuration easily. This type of information is stored in CMOS RAM so that it is retained during power-off periods.
  • Page 70: Entering Setup -- Launch System Setup

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.1 Entering Setup -- Launch System Setup Power on the computer and the system will start POST (Power On Self Test) process. When the message below appears on the screen, press <Del> key will enter BIOS setup screen.
  • Page 71: Main

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.2 Main Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 72: Advanced

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.3 Advanced Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 73: Trusted Computing

    COM Express™ PORTWELL PCOM-B700G User's Guide Trusted Computing Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 74: Acpi Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide ACPI Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 75: Isio Super Io Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide ISIO Super IO Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 76: Serial Port (1~2) Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Serial Port (1~2) Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 77: Isio Hardware Monitor

    COM Express™ PORTWELL PCOM-B700G User's Guide ISIO Hardware Monitor Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 78: Rtc Wakeup

    COM Express™ PORTWELL PCOM-B700G User's Guide RTC Wakeup Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 79: Serial Port Console Redirection

    COM Express™ PORTWELL PCOM-B700G User's Guide Serial Port Console Redirection Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 80: Console Redirection Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide Console Redirection Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 81: Legacy Console Redirection Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide Legacy Console Redirection Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 82: Pci Subsystem Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Subsystem Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 83: Pci Express Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 84: Pci Express Gen 2 Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express GEN 2 Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 85: Pci Hot-Plug Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Hot-Plug Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 86: Network Stack Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Network Stack Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 87: Csm Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide CSM Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 88: Info Report Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Info Report Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 89: Usb Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide USB Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 90: Intelrcsetup

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.4 IntelRCSetup Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 91: Processor Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Processor Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 92: Advanced Power Management Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Advanced Power Management Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 93: Cpu P State Control

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU P State Control Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 94: Xe Ratio Limit

    COM Express™ PORTWELL PCOM-B700G User's Guide XE Ratio Limit Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 95: Cpu C State Control

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU C State Control Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 96: Cpu T State Control

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU T State Control Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 97: Cpu Thermal Management

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU Thermal Management Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 98: Cpu Advanced Pm Turning

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU Advanced PM Turning Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 99: Energy Perf Bias

    COM Express™ PORTWELL PCOM-B700G User's Guide Energy Perf BIAS Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 100: Program Powerctl_Msr

    COM Express™ PORTWELL PCOM-B700G User's Guide Program PowerCTL_MSR Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 101: Program Ppo_Curt_Cfg_Ctrl_Msr

    COM Express™ PORTWELL PCOM-B700G User's Guide Program PPO_CURT_CFG_CTRL_MSR Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 102: Psi Config

    COM Express™ PORTWELL PCOM-B700G User's Guide PSI CONFIG Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 103: Program Csr_Entry_Criteria

    COM Express™ PORTWELL PCOM-B700G User's Guide Program CSR_ENTRY_CRITERIA Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 104: Cpu(0~3) Advanced Pm Turning

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU(0~3) Advanced PM Turning Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 105: Program Csr_Swl Trovrd

    COM Express™ PORTWELL PCOM-B700G User's Guide Program CSR_SWL TROVRD Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 106: Dram Rapl Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide DRAM RAPL Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 107: Socket Rapl Config

    COM Express™ PORTWELL PCOM-B700G User's Guide SOCKET RAPL Config Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 108: Common Refcode Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Common Refcode Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 109: Qpi Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide QPI Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 110: Qpi General Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide QPI General Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 111: Qpi Per Socket Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide QPI Per Socket Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 112: Cpu (0~3)

    COM Express™ PORTWELL PCOM-B700G User's Guide CPU (0~3) Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 113: Memory Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 114: Memory Topology

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Topology Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 115: Memory Thermal

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Thermal Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 116: Memory Power Savings Advanced Options

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Power Savings Advanced Options Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 117: Memory Timings & Voltage Override

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Timings & Voltage Override Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 118: Memory Map

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Map Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 119: Memory Ras Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory RAS Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 120: Iio Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide IIO Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 121: Iio (0~3) Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide IIO (0~3) Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 122: Ioat Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide IOAT Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 123: Iio General Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide IIO General Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 124: Intel Vt For Directed I/O (Vt-D)

    COM Express™ PORTWELL PCOM-B700G User's Guide Intel VT for Directed I/O (VT-d) Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 125: Iio South Complex Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide IIO South Complex Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 126: Pch Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide PCH Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 127: Pch Devices

    COM Express™ PORTWELL PCOM-B700G User's Guide PCH Devices Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 128: Pci Express Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 129: Pci Express Root Port 1~8

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI Express Root Port 1~8 Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 130 COM Express™ PORTWELL PCOM-B700G User's Guide Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 131: Pch Sata Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide PCH SATA Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 132: Sata Mode Options

    COM Express™ PORTWELL PCOM-B700G User's Guide SATA Mode options Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 133: Usb Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide USB Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 134: Security Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Security Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 135: Networking

    COM Express™ PORTWELL PCOM-B700G User's Guide Networking Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 136: Platform Thermal Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Platform Thermal Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 137: Miscellaneous Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Miscellaneous Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 138: Server Me Debug Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Server ME Debug Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 139: Server Me General Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Server ME General Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 140: Override Icc Clock Enables

    COM Express™ PORTWELL PCOM-B700G User's Guide Override ICC Clock Enables Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 141: Nm Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide NM Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 142: Server Me Configuration

    COM Express™ PORTWELL PCOM-B700G User's Guide Server ME Configuration Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 143: Runtime Error Logging

    COM Express™ PORTWELL PCOM-B700G User's Guide Runtime Error Logging Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 144: Whea Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide Whea Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 145: Memory Error Enabling

    COM Express™ PORTWELL PCOM-B700G User's Guide Memory Error Enabling Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 146: Iio Error Enable

    COM Express™ PORTWELL PCOM-B700G User's Guide IIO Error Enable Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 147: Iio Coherency Interface Error Enable

    COM Express™ PORTWELL PCOM-B700G User's Guide IIO Coherency Interface Error Enable Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 148: Pci/Pci Error Enabling

    COM Express™ PORTWELL PCOM-B700G User's Guide PCI/PCI Error Enabling Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 149: Reserve Memory

    COM Express™ PORTWELL PCOM-B700G User's Guide Reserve Memory Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 150: Security

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.5 Security Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 151: Boot

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.6 Boot Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 152: Uefi Usb Key Drive Bbs Priorities

    COM Express™ PORTWELL PCOM-B700G User's Guide UEFI USB key Drive BBS Priorities Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 153: Event Logs

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.7 Event Logs Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 154: Change Smbios Event Log Settings

    COM Express™ PORTWELL PCOM-B700G User's Guide Change Smbios Event Log Settings Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 155: View Smbios Event Log

    COM Express™ PORTWELL PCOM-B700G User's Guide View Smbios Event Log Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 156: Save & Exit

    COM Express™ PORTWELL PCOM-B700G User's Guide 6.8 Save & Exit Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 157: System Resources

    COM Express™ PORTWELL PCOM-B700G User's Guide 7 System Resources Device I/O Address Note Embedded Controller (ITE8528) 0x6E / 0x6F EC Address 0x62 / 0x66 EC ACPI CMD Port 0x200 / 0x201 EC BRAM Port for I2C function 0x1300~0x13FF EC LPC IO Space...
  • Page 158: Bios Update

    COM Express™ PORTWELL PCOM-B700G User's Guide 8 BIOS Update BIOS/EC DOS Update SOP process Step 1. Create a DOS USB DOK. (Must be FAT or FAT32 format) Step 2. Unzip update file to the DOS USB DOK. Copyright © PORTWELL 2018...
  • Page 159 COM Express™ PORTWELL PCOM-B700G User's Guide Step 3. Plug the DOS USB DOK into the target system and boot from the DOS USB DOK. Step 4. Under the update file folder, type command : "update" and press enter. Copyright © PORTWELL 2018...
  • Page 160 COM Express™ PORTWELL PCOM-B700G User's Guide Step 5. The update process will start and you can see the updating progress. Once finished, please power off and restart the system. <End of BIOS/EC DOS update process> Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 161 COM Express™ PORTWELL PCOM-B700G User's Guide BIOS/EC UEFI Update SOP process Step 1. Prepare a USB DOK. (Must be FAT or FAT32 format) Step 2. Unzip update file to the USB DOK. Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 162 COM Express™ PORTWELL PCOM-B700G User's Guide Step 3. Select UEFI boot mode in the BIOS boot menu and save, then restart the system. Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 163 COM Express™ PORTWELL PCOM-B700G User's Guide Step 4. Plug the USB DOK into the target system and boot from UEFI Shell. Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 164 COM Express™ PORTWELL PCOM-B700G User's Guide Step 5. Under the UEFI shell, direct to your USB DOK, below is an example uses fs0. Then direct to the folder with updated file and type command : "update" and press enter. Copyright © PORTWELL 2018...
  • Page 165 COM Express™ PORTWELL PCOM-B700G User's Guide Step 6. The updating process will start and you can see the updating progress. Once finished, please power off and restart the system. <End of BIOS/EC UEFI update process> Copyright © PORTWELL 2018 PCOM-B700G User's Guide...
  • Page 166: Portwell Software Tool

    Windows and Linux OS. For more information please contact PORTWELL. PORTWELL BIOS web Tool (PBT) The PORTWELL BIOS web Tool (PBT) is a brand new on-line utility innovated by PORTWELL. PBT now is available for PORTWELL's premiere customers who are able to...
  • Page 167: Industry Specifications

    COM Express™ PORTWELL PCOM-B700G User's Guide 10 Industry Specifications The list below provides links to industry specifications that apply to PORTWELL modules. Low Pin Count Interface Specification, Revision 1.0 (LPC) http://www.intel.com/design/chipsets/industry/lpc.htm Universal Serial Bus (USB) Specification, Revision 2.0 http://www.usb.org/home PCI Specification, Revision 2.3 https://www.pcisig.com/specifications...

Table of Contents