Remote indicator with foundation fieldbus protocol (12 pages)
Summary of Contents for Emerson RXi
Page 1
Quick Start Guide GFK-3072B Feb 2020 RXi – Panel PC QUICK START GUIDE...
Page 2
It is understood that Emerson may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the Emerson products referenced herein.
Operation Status LEDs (Screen) ..............19 Ethernet Port Operation LEDs ................. 19 Mounting Information .............. 20 Panel Mount ....................... 20 Panel Cutout Dimensions ................. 20 Installation Steps ....................21 Mounting to Modular Display ..................22 RXi – Panel PC Quick Start Guide GFK-3072B...
Page 4
VESA Mount ....................... 25 VESA Mount Dimensions ................. 25 Product Revision History ............30 RXi – Panel PC Quick Start Guide GFK-3072B...
ChChanges or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Industry Canada requires the following to be published: CAN ICES-3 (A)/NMB-3 (A) RXi – Panel PC Quick Start Guide GFK-3072B...
Environmental conditions as identified in Section 1.1 shall be followed during installation and operation. Intended Use The RXi Panel PC is intended for use in industrial environments only. Adherence to supplied documentation is part of the intended use. Installation, commissioning, and maintenance shall be carried out by qualified personnel.
5. Apply dc power to the unit. During normal startup and operation, the LED status indicator displays as follows: • Solid amber while the RXi - Industrial Display unit is starting up • Solid green during normal operation 6. Once power is applied, the unit begins initializing. The first thing to display is the splash screen.
The USB ports allow for data exchange between your computer and a wide range of simultaneously accessible external Plug and Play peripherals. The RXi – Panel PC is equipped with 2 onboard USB 3.0 ports (USB 0-1) in the small configuration with an additional 2 USB 2.0 ports (USB 4-5) in the large box configuration.
Configure the Serial ATA drive in the Chipset menu (“SB SATA Configuration” submenu) of the BIOS. Refer to chapter 3 for more information. Expansion Slots Micro SD Socket The micro SD socket allows you to install a micro SD card for the expansion of available storage. RXi – Panel PC Quick Start Guide GFK-3072B...
Replace Battery with Panasonic, type CR2032 only. Use of Another Battery May Present a Risk of Fire or Explosion. CAUTION Battery May Explode if Mistreated. Do not Recharge, Disassemble, or Dispose of In Fire. Figure 8: Battery Replacement RXi – Panel PC Quick Start Guide GFK-3072B...
LED Indicators Operation Status LEDs (Screen) All RXi Industrial Displays have a tri-color LED built into the screen that provides visual indication of the operation status. LED State System State Amber, Solid Operating system starting Green, Solid Normal operating state...
Mounting Information Panel Mount The RXi Panel PC can be panel-mounted as shown in figures below. A Type 4, Type 4X, or IP 66 rating is achieved, when following instructions provided below and mounting to the flat surface of a sufficiently rated enclosure.
In a cross pattern around the monitor tighten all mounting clip screws to a torque of 13 to 13.9 in- lbs. (15 to 16kgf-cm) making sure not to overtighten the bracket. Figure 12: Tighten Mounting Bracket RXi – Panel PC Quick Start Guide GFK-3072B...
Mounting to Modular Display Figure 13: 7" Mount Figure 14: 10" mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 24
Figure 15: 12" Mount Figure 16: 15" Mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 25
Figure 17: 19/24" Mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 26
VESA Mount VESA Mount Dimensions The RXi Panel PC can also be VESA mounted as shown in figures below. All 7” through 24” units include VESA Mount Dimensions of 100mm x 100mm. All units fastened with four M4x8 screws. Figure 18: 7" VESA Mount RXi –...
Page 27
Figure 19: 10" VESA Mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 28
Figure 20: 12" VESA Mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 29
Figure 21: 15" VESA Mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 30
Figure 22: 19"/24" VESA Mount RXi – Panel PC Quick Start Guide GFK-3072B...
Page 31
Product Revision History Revision Description 2020/02/04 • Download and install Chrome (VPN to USA) (SW Image) RXi – Panel PC Quick Start Guide GFK-3072B...
Page 32
Note: If the product is purchased through an Authorized Channel Partner, please contact the seller directly for any support. Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product.