Quick Start Guide
00825-0100-4377, Rev EB
February 2019
Rosemount
752 Remote Indicator
with F
Fieldbus Protocol
OUNDATION

Advertisement

loading

Summary of Contents for Emerson Rosemount 752

  • Page 1 Quick Start Guide 00825-0100-4377, Rev EB February 2019 ™ Rosemount 752 Remote Indicator ™ with F Fieldbus Protocol OUNDATION...
  • Page 2: Table Of Contents

    This guide provides basic guidelines for Rosemount 752 Remote Indicator. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations. Refer to the Rosemount 752 Reference Manual more instruction. Thismanual is also available electronically on Emerson.com/Rosemount.
  • Page 3: Wiring Connection

    February 2019 Quick Start Guide Wiring connection Wiring for F Fieldbus protocol OUNDATION 1. Remove the housing cover on terminal compartment side. Note Do not remove the cover in explosive atmospheres when the circuit is live. Signal wiring supplies all power to the indicator. 2.
  • Page 4 Shield wire ground To protect the Fieldbus segment from noise, grounding techniques for shield wire usually require a single grounding point for shield wire to avoid creating a ground loop. The ground point is typically at the power supply. Rosemount 752...
  • Page 5 February 2019 Quick Start Guide Figure 1-2: F Fieldbus Indicator Field Wiring OUNDATION Power supply OUNDATION Fieldbus configuration tool Intrinsically safe installations may allow fewer devices per I.S. barrier due to current limitations. A. Integrated power conditioner and filter B. 6234 ft. (1900 m) max (depending upon cable characteristics) C.
  • Page 6 The internal ground connection screw is inside the terminal side of the electronics housing. The screw is identified by a ground symbol ( ), and is standard on the Rosemount 752 Remote Indicators. External ground assembly Ground screw is located at the bottom of the mounting bracket.
  • Page 7: Configure The Transducer Block

    752 that links a process variable from another device on the segment, that process variable can be displayed on the LCD display. To configure the Rosemount 752 Fieldbus Indicator use any F OUNDATION Fieldbus configuration tool to modify the configuration parameters for each value that is to be displayed.
  • Page 8 CUSTOM_UNITS_# Specify custom units to be displayed with the parameter. Enter up to six characters. To display Custom Units the UNITS_TYPE_# must be set to CUSTOM. Note _# represents the specified parameter number. Rosemount 752...
  • Page 9: Product Certification

    A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that...
  • Page 10 2. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. Rosemount 752...
  • Page 11 EN 60079-11:2012. This must be taken into account during installation. 2. The Rosemount 752 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0 area.
  • Page 12 500 V test as defined in Clause 6.3.13 of IEC 60079-11:2011. This must be taken into account during installation. 2. The Rosemount 752 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact of abrasion if located in a zone 0 area.
  • Page 13 February 2019 Quick Start Guide NF IECEx Dust Certificate: IECEx KEM 10.0066X Standards: IEC 60079-0:2011, EN 60079-31:2013 Markings: Ex tb IIIC T105 °C Db (–60 °C ≤ T ≤ 80 °C); IP66 Special Conditions for Safe Use (X): 1. Flameproof joints are not intended for repair. 2.
  • Page 14 KA Combination of E1, E6, I1, and I6 KB Combination of E5, E6, I5, and I6 KC Combination of E5, E1, I5, and I1 KM Combination of EM, IM, and NM Table 3-1: Entity Parameters Parameters Fieldbus FISCO 17.5 Rosemount 752...
  • Page 15 February 2019 Quick Start Guide Table 3-1: Entity Parameters (continued) Parameters Fieldbus FISCO (mA) 5.32 Quick Start Guide...
  • Page 16: Declaration Of Conformity

    Quick Start Guide February 2019 Declaration of Conformity Rosemount 752...
  • Page 17 February 2019 Quick Start Guide Quick Start Guide...
  • Page 18 Quick Start Guide February 2019 Rosemount 752...
  • Page 19: China Rohs

    February 2019 Quick Start Guide China RoHS China RoHS Rosemount 752 List of Rosemount 752 Parts with China RoHS Concentration above MCVs Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6)
  • Page 20 The Emerson logo is a Facebook.com/Rosemount trademark and service mark of Emerson Electric Youtube.com/user/ Co. Rosemount is mark of one of the Emerson RosemountMeasurement family of companies. All other marks are the Google.com/+RosemountMeasurement property of their respective owners.