9.
Place motors back on the motor plate. Replace the motor hold
down plate, ensure wires sit above the plate, ensure the tabs on the
motors line up with the notches on the hold down plate.
10. Re-wire the motors.
a. There is no polarity.
b. DO NOT tamper with the grounding wire.
c. Keep wiring consistent, the same wire from each
motor should be inserted into the same lever nut.
d. Open lever and insert one wire into each hole in
lever nut. Close lever and make sure each wire is
secure.
LEVER
NUT
MOTOR
1 2 3 4 5
Wire 1
Wire 2
Ground Wire
Magnetic Starter Wire
Dust Sentry Wire
System Power Wire
DETAIL F
DETAIL F
SCALE 2 : 1
SCALE 2 : 1
F
F
MOTOR
MOTOR
5 4 3 2 1
LEVER
NUT
SWITCH BOX
11. Re-secure the motor hold down plate using the five 5/16-18"
Nylock Nuts.
Note: DO NOT OVERTIGHTEN. Install the provided spacers over
the threaded studs to determine the correct depth to drive the nuts.
12. Replace the plenum plate.
13. Re-install the molded cowling and the Nylock nut that secures it.
Clean then install the filter foam on top of the molded cowling.