Manual
Electrical code R, 460 V/3-ph/60 Hz; units with reciprocating compressors
CH
Electrical code Q, 230 V/3-ph/60 Hz; units with scroll compressors
PE
GREEN
COMPRESSOR
POWER
12
FRCC.ES.013.A1.02
Installation & Maintenance
POWER PACK
CH
CH
HP
FAN 1
FAN 2
(OPTIONAL)
MP
LP
PRESSURE
SWITCH
FROM HIGH
SEQUENCE PHASE RELAY
Legend
CP
Compressor
FC
Fan capacitor
MP
Motor protector
K
Contactor
HP
High-pressure switch
LP
Low-pressure switch
CH
Crankcase heater
F1-F2
Fan
PRESSURE
SWITCH
FROM LOW
BLACK
BLACK
PE
GREEN
Need help?