Ashley AP130 Owner’s Instruction And Operation Manual

Ashley AP130 Owner’s Instruction And Operation Manual

Advertisement

Available languages

Available languages

Owner's Instruction and Operation Manual
Model Number:
AP130
Report Number: F20-570
Certified to ASTM E1509-12 (2017),
and Certified to ULC-S627-00-REV1
Mobile Home Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Could Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
853146K-0202K
Ph. 800-750-2723

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AP130 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ashley AP130

  • Page 1 Owner’s Instruction and Operation Manual Model Number: AP130 Report Number: F20-570 Certified to ASTM E1509-12 (2017), and Certified to ULC-S627-00-REV1 Mobile Home Approved 853146K-0202K * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. Save These Instructions In A Safe Place For Future Reference.
  • Page 2 Your pellet stove has been safety tested and listed to ASTM E1509-12 (2017), ULC-S627-00. This manual describes the installation and operation of the Ashley, AP130 pellet stove. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood-heaters sold after May 15, 2020.
  • Page 3: Installation Checklist

    INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4: Installation

    INSTALLATION FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 SAFETY NOTICE CAUTION: • IF THIS STOVE IS NOT PROPERLY INSTALLED, BURNING FUEL CREATES CARBON MONOXIDE A HOUSE FIRE MAY RESULT. TO REDUCE THE AND CAN BE HAZARDOUS TO YOUR HEALTH RISK OF FIRE, FOLLOW THE INSTALLATION IF NOT PROPERLY VENTED.
  • Page 5: Installation Options

    INSTALLATION INSTALLATION OPTIONS CLEARANCES Freestanding Unit - Supported by pedestal/legs Your pellet stove has been tested and listed for and placed on a non-combustible floor surface installation in residential, mobile home, and alcove in compliance with clearance requirements for a applications in accordance with the clearances freestanding stove installation.
  • Page 6: Venting Requirements

    INSTALLATION • Outside Air is mandatory for mobile home ATTENTION: installation. See Outside Air Supply section and DO NOT VENT UNDER ANY PORCH, DECK, your dealer for purchasing. AWNING, OR IN ANY SEMI ENCLOSED OR • Check with your local building officials as other ROOFED AREA.
  • Page 7: Pellet Vent Type

    INSTALLATION PELLET VENT TERMINATION draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and Do not terminate the vent in an enclosed or semi- other factors. Too much draft may cause excessive enclosed area, such as; carport, garage, attic, temperatures appliance.
  • Page 8: Through The Wall Installation

    INSTALLATION E. Minimum 2-foot (0.61m) clearance above any wall and a clean out tee should be placed on the grass, plants, or other combustible materials. pipe with a 90-degree turn away from the house. At this point, a 3ft (0.91m) (minimum) section of F.
  • Page 9: How Your Stove Works

    OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED or aggressive. The flame in this situation is typically HOW YOUR STOVE WORKS very blue at the bottom and resembles a blow torch. If this situation continues, the fuel in the burn pot 4 Digit Display will be consumed and the fire will go out.
  • Page 10: Control Panel Overview

    OPERATION INSTRUCTIONS on the heat range “1” setting. again to adjust fan speed. When the heater is in the manual mode, the optional thermostat will • During start up the heat level advance (Up and not properly control the unit. When adjusting the Down keys) will change the heat range indicator Draft Fan setting, try only 1 setting above or below level accordingly, but there is no change in the...
  • Page 11: Thermostat Hook-Up

    OPERATION INSTRUCTIONS THERMOSTAT HOOK-UP The Jumper Must Be Removed First 1. Put female terminals on the lead wires to your low voltage thermostat. 2. Plug one thermostat lead onto each of the terminal posts on the circuit board. IMPORTANT NOTE: The purpose of the T’Stat is make stove...
  • Page 12: Proper Fuel

    OPERATION INSTRUCTIONS Your pellet stove is designed to burn premium WARNING: hardwood pellets that comply with the Pellet Fuels • DO NOT USE CHEMICALS OR FLUIDS TO Institute (PFI) standard (minimum of 40 lbs density START THE FIRE - NEVER USE GASOLINE, per cubic ft, 1/4”...
  • Page 13 OPERATION INSTRUCTIONS If the door is opened while the stove is in operation CAUTION: it must be closed within 30 seconds or the stove • KEEP FOREIGN OBJECTS OUT OF THE will shut down. If the stove shuts down push the HOPPER.
  • Page 14: Shutdown Procedure

    OPERATION INSTRUCTIONS REFUELLING and shut down the fuel feed or auger system. B. In case malfunctioning convection blower, the high-temperature thermodisc will WARNING: automatically shut down the auger, preventing the stove from overheating. • KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING.
  • Page 15: Maintenance

    MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED at the chimney top. Cooler surfaces tend to build CAUTION: creosote deposits quicker, so it is important to • FAILURE TO CLEAN AND MAINTAIN THIS check the chimney from the top as well as from the UNIT AS INDICATED CAN RESULT IN POOR bottom.
  • Page 16: Blower Motors

    MAINTENANCE for extended periods of time. While the modern Once the heater has cooled, remove the door combustion systems in heaters drastically reduce from the heater. the amount of CO emitted out the chimney, 2. Remove the rope gasket from the door followed exposure to the gases in closed or confined areas by the nuts holding the glass retainer in place.
  • Page 17: Maintenance Schedule

    MAINTENANCE MAINTENANCE SCHEDULE Monthly or Weekly Daily Use the following as a guide under average use as needed conditions. Gaskets around door and door glass Burn Pot Stirred Empty should be inspected and repaired or replaced when necessary. Combustion Brushed Chamber Ashes Check...
  • Page 18: Troubleshooting

    TROUBLE SHOOTING • Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical components of the stove. • Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other work should be done by a trained technician.
  • Page 19: Display Indicators

    TROUBLE SHOOTING Error Code Error Description Possible Causes Inadequate ventilation. The high limit temperature sensor Room fan failure. Err1 Exhaust Blockage. has tripped. Electrical Open in wiring. Hopper Empty. Auger output failure or jam. Flame of fuel quality caused fire to burn too slowly Stove ran out of fuel during normal Err2 or go out.
  • Page 20: Parts Diagram

    PARTS DIAGRAM © 2021 United States Stove Company...
  • Page 21 Exhaust Duct Gasket 88117 Exhaust Blower 80473 IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2021 United States Stove Company...
  • Page 22 To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
  • Page 23: Wiring Diagram

    WIRING DIAGRAM BLACK GRAY Ensure the wires are connected to the bottom two prongs of the hopper switch as shown. CORRECT WRONG HOW TO ORDER REPAIR PARTS For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: parts@usstove.com The information in this owner’s manual is specific to your unit. When ordering replacement parts the information in this manual will help to ensure the correct items are ordered.
  • Page 24: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 25 NOTES © 2021 United States Stove Company...
  • Page 26 NOTES © 2021 United States Stove Company...
  • Page 27 ENREGISTREMENT DE SERVICE Il est recommandé que votre système de chauffage est desservi régulièrement et que le Service Interval enregistrement approprié est terminée. FOURNISSEUR DE SERVICES Avant de terminer l’enregistrement de service approprié ci-dessous, s’il vous plaît vous assurer que vous avez effectué le service tel que décrit dans le les instructions du fabricant.
  • Page 28: Schéma De Câblage

    SCHÉMA DE CÂBLAGE MOTEUR BLANC D'ENTRAÎNEMENT DE LA VIS SANS FIN SOUFFLANTE DE DISTRIBUTION NOIR BLANC MICRORUPTEUR PRESSOSTAT NOIR PRISE MOLEX AU CIRCUIT IMPRIMÉ BLANC MARRON MARRON NOIR GRIS ALLUMEUR VENTILATEUR D'ÉVACUATION PRINCIPAL SOURCE ÉLECTRIQUE THERMISTOR ALLUMEUR BLANC NOIR ASSUREZ-VOUS QUE LES FILS SONT CONNECTÉS DEUX BROCHES...
  • Page 29: Pièces De Rechange

    PIÈCES DE RECHANGE Clé Réf La description Qté 891135 Poignée à ressort 25492 Poignée, porte Goupille cylindrique 3/8 x 1-1 / 4 83506 Porte d'alimentation 25507 Joint de corde 5/8 po 4,5 pi 88066 891053 Verre de porte Retenue en verre supérieure 25521 Retenue de verre inférieure 25520...
  • Page 30 Épingle À Cheveux AFIN DE MAINTENIR LA GARANTIE, LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS À L’AIDE DE PIÈCES ASHLEY ACHETÉES VIA VOTRE CONCESSIONNAIRE OU DIRECTEMENT À ASHLEY. L’UTILISATION DE COMPOSANTS DE TIERS ANNULERA LA GARANTIE. © 2021 United States Stove Company...
  • Page 31 PIÈCES DE RECHANGE © 2021 United States Stove Company...
  • Page 32: Calendrier D'entretien

    ENTRETIEN CALENDRIER D’ENTRETIEN Tous les Suivez le calendrier ci-dessous dans des conditions Tous les Toutes les mois ou d’utilisation moyennes. Les joints autour de la porte et de jours semaines selon les la vitre doivent être inspectés et réparés ou remplacés si besoins nécessaire.
  • Page 33 ENTRETIEN Aspirez les cendres de la chambre de combustion. d’acier et de l’eau pour nettoyer le verre. N’UTILISEZ PAS de ASSUREZ-VOUS QUE LES CENDRES SONT FROIDES nettoyants abrasifs. N’effectuez PAS le nettoyage lorsque AU TOUCHER AVANT D’ASPIRER. Certains aspirateurs la vitre est CHAUDE. N’essayez pas de faire fonctionner peuvent laisser échapper des cendres dans la pièce.
  • Page 34 ENTRETIEN NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE à accumuler les dépôts de créosote plus rapidement; il AVERTISSEMENT: est donc important de vérifier la cheminée par le haut • LE DÉFAUT DE NETTOYAGE ET D’ENTRETIEN ainsi que par le bas. La créosote doit être éliminée DE CET APPAREIL COMME INDIQUÉ...
  • Page 35: Instructions D'utilisation

    INSTRUCTIONS D’UTILISATION refroidi. Le fabricant vous recommande de vous adresser AVERTISSEMENT: au revendeur si cela se produit car cela peut indiquer un • LA TRÉMIE ET LE COUVERCLE DU POÊLE SONT problème plus grave. Il peut s’avérer nécessaire d’appeler CHAUDS PENDANT LE FONCTIONNEMENT ; le service de réparation.
  • Page 36 INSTRUCTIONS D’UTILISATION Ajustez la vitesse d’alimentation au réglage souhaité AVERTISSEMENT: en appuyant sur le bouton «Avance du niveau de • GARDER LES OBJETS ÉTRANGERS HORS DE LA chaleur». TRÉMIE. Si le feu ne démarre pas dans 12 minutes, appuyez sur •...
  • Page 37 INSTRUCTIONS D’UTILISATION Votre poêle à granulés est conçu pour brûler des granulés AVERTISSEMENT: de bois dur de qualité supérieure conformes à la norme • N'UTILISEZ PAS DE PRODUITS CHIMIQUES OU PFI (Pellet Fuels Institute) (densité minimale de 40 lb par DE FLUIDES POUR ALLUMER LE FEU - N'UTILISEZ pied cube, diamètre de 1/4 à...
  • Page 38 INSTRUCTIONS D’UTILISATION RACCORDEMENT DU THERMOSTAT Le cavalier doit être enlevé en premier 1. Placez les bornes femelles sur les fils conducteurs de votre thermostat basse tension. 2. Branchez un fil de thermostat sur chacun des bornes du circuit imprimé. REMARQUE IMPORTANTE: L’objet du T’Stat est de faire en sorte que le poêle se programme entre le réglage présélectionné...
  • Page 39 INSTRUCTIONS D’UTILISATION • Après avoir appuyé sur “Power”, le moteur de la vis est de combustible qui est approvisionnée au pot de activé pendant 3,5 minutes, éteint pendant 1 minute. combustion. Pendant le reste de la période de démarrage, le moteur •...
  • Page 40 INSTRUCTIONS D’UTILISATION NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE hyperactive ou agressive. La flamme dans cette situation COMMENT FONCTIONNE VOTRE POÊLE est généralement très bleue à la base et ressemble à celle d’un chalumeau. Si cette situation persiste, le Afficheur à 4 chiffres combustible dans le pot de combustion sera consumé...
  • Page 41: Installation

    INSTALLATION Dégagement minimum de 2 pi. (0,61 m) au-dessus de À ce stade, une section de 3 pieds (0,91 m) (minimum) toute plante, herbe ou autre matériau combustible. de la conduite devrait être ajouté avec un bouchon horizontale, qui viendrait compléter l’installation. Une Dégagement minimum de 3 pi.
  • Page 42 INSTALLATION horizontale NE DOIT PAS dépasser 4 pi (1,22 m). Ceci moyens pour maintenir le pare-vapeur entre l’extérieur pourrait provoquer une contre-pression. N’utilisez pas et l’intérieur de la maison. Les surfaces de ventilation plus de 180 degrés de coudage (deux coudes à 90 degrés, peuvent devenir suffisamment chaudes pour provoquer ou deux coudes à...
  • Page 43 INSTALLATION • L’évent doit être de 3 ou 4 po «PL» et doit dépasser d’au ALIMENTATION EN AIR EXTÉRIEUR moins 36 po (914 mm) au-dessus de la ligne de toit OPTION, SAUF SI INSTALLÉ DANS UNE MAISON MOBILE) de la maison mobile et doit être installé à l’aide d’un Selon votre emplacement et la construction de votre coupe-feu de plafond certifié...
  • Page 44: Options D'installation

    INSTALLATION OPTIONS D’INSTALLATION DÉGAGEMENTS Unité autoportante - supportée par un piédestal / pieds Votre poêle à granulés a été testé et homologué pour et placée sur une surface de plancher incombustible une installation dans des applications résidentielles, conformément aux exigences de dégagement pour une de maisons mobiles et en alcôve conformément aux installation de poêle autoportante.
  • Page 45 INSTALLATION POUR LE SERVICE À LA CLIENTÈLE APPELER: 800-750-2723 EXT 5050 AVIS DE SÉCURITÉ ATTENTION: • SI CE POÊLE N’EST PAS INSTALLÉ CORRECTEMENT, • UN DÉTECTEUR DE FUMÉE FONCTIONNEL DOIT INCENDIE PEUT RÉSULTER. POUR ÊTRE INSTALLÉ DANS LA PIÈCE OÙ SE TROUVE RÉDUIRE LES RISQUES D’INCENDIE, SUIVEZ LES LE POÊLE.
  • Page 46: Liste De Contrôle D'installation

    LISTE DE CONTRÔLE D’INSTALLATION Votre poêle à bois ne doit être installé que par un installateur qualifié. Un installateur qualifié NFI est disponible à l’adresse www.nficertified.org/public/find-an-nfi-pro/ SERVICE CLIENTS 1-800-750-2723 poste 5050 Texte au 423-301-5624 E-mail à: customerservice@usstove.com LISTE DE CONTRÔLE DE MISE EN SERVICE Cette liste de contrôle doit être remplie intégralement par la personne qualifiée qui installe cet appareil.
  • Page 47 Votre poêle à pellets a été testé et répertorié conformément aux normes ASTM E1509-12 (2017), ULC-S627-00. Ce manuel décrit l’installation et le fonctionnement du poêle à granulés Ashley modèle AP130. Cet appareil de chauffage respecte les limites d’émission de bois en vigueur aux États-Unis en vertu de l’Environmental Protection Agency des États-Unis pour les appareils de chauffage au bois vendus après le 15 mai 2020.
  • Page 48 Manuel D’instructions et D’utilisation Du Propriétaire Numéro De Modèle: AP130 Numéro de rapport: F20-570 Certifié selon ASTM E1509-12 (2017) et certifié ULC-S627-00-REV1 Mobile Home Approuvé * Toutes les images de ce manuel sont à des fins d’illustration uniquement. Le produit réel peut varier.

Table of Contents