General data
Isolation
Power circuitry – input circuit
Power circuitry – output circuit
Input circuit - output circuit
Weight
Climatic conditions
Climatic conditions acc. to
Ambient operating temperature T
Storage temperature
Relative humidity
Air pressure in operation
Mechanical strength
Vibration acc. to
Electrical safety
Protection class housing / terminals acc. to EN 60529
Finger-proof
Clearance/creepage distance
EMC
Overvoltage category
Contamination level
Terminals and connection
Single-core or finely stranded
Stripping length
Finely stranded with wire-end ferrule to DIN 46228
Max. tightening torque
* The operate time is the time between the OFF signal arriving at the input terminals and the outputs actually being shut down (in normal operation).
The times for output expansions must be added (e.g. SA-OR).
Diagram of connections
Dimensions
SA-BM-S1-4EKL-A
B
no
no
no
0.16 kg
EN 61131-2
-25C to +55C
-25C to +70C
10% to 95%, no condensation
860 hPa to 1060 hPa
EN 60068-2-xx (more data see manual)
IP 40 / IP 20
EN 50247
EN 61131-2
EN 61000-4-xx (more data see manual)
III
2 inside, 3 outside
screw-type terminals
1 x 0.2 - 2.5 mm² / 2 x 0.2 - 0.75 mm²
1 x 0.25 - 2.5 mm² / 2 x 0.25 - 0.5 mm²
0.5 to 0.6 Nm
Diagram Total current vs. ambient temperature
SA-BM-S1-4EKL-C
spring-type terminals
2 x 0.2 - 1.5 mm²
max. 8 mm
2 x 0.25 - 1.5 mm² (trapezoid crimping)
---
11