Theoretical Output; Kinetic Energy Absorbed By Cushion Mechanism - SMC Networks CS2 Operation Manual

Air cylinder
Table of Contents

Advertisement

5)

Theoretical output

Table 3. Double acting cylinder theoretical output
Bore
Rod
Operating
size
diameter
direction
(mm)
(mm)
OUT
125
32
IN
OUT
140
32
IN
OUT
160
38
IN

6) Kinetic energy absorbed by cushion mechanism

Table 4. Kinetic energy absorbed
Bore size
(㎜)
125
140
160
Warning
A deceleration circuit or shock absorber may be required.
When a driven object is operated at high speed or the load is heavy, a
cylinder's cushion will not be sufficient to absorb the shock. Install a
deceleration circuit to reduce the speed before cushioning, or install an
external shock absorber to relieve the shock. In this case, the rigidity of the
machinery should also be examined.
Pressurized
area
0.3
2
(mm
12300
3690
11500
3440
15400
4620
14600
4380
20100
6030
19000
5690
Effective cushion length
(㎜)
21.0
21.0
21.0
- 9 -
OUT
Operating pressure(MPa)
0.5
0.7
6150
8610
5750
8030
7700
10200
7290
10100
10100
14100
9490
13300
Absorbable kinetic energy
IN
(N)
0.9
11100
10300
13900
13100
18100
17100
(J)
32.3
44.6
58.8

Advertisement