PACK OVERLOAD
EICAS Caution: PACK 1 (2) OVLD
LIGHT: Master Caution
Associated Temperature & Mode Selector................... AUTO/
Associated Pack ........................................................... OFF
Wait 3 minutes.
Associated Pack ........................................................... ON
NOTE: In case the message still displayed after reset, report to the
maintenance personnel.
If the message remains on:
Associated Temperature & Mode Selector.............. MANUAL/
Associated Pack ...................................................... OFF
Wait 3 minutes.
Associated Pack ...................................................... ON
If the message still remains on:
Associated Pack ...................................................... OFF
Altitude..................................................................... MAX 25000 ft
Associated Engine Bleed......................................... OPEN
If both packs have been shutoff:
Altitude..................................................................... MEA OR
Pressurization Mode Selector.................................. MAN
Pressurization Manual Controller ............................ AS REQUIRED
If required:
Pressurization Manual Controller ....................... FULL UP
NOTE: At least one bleed source, engines or APU, must be kept
open.