NORMAL PROCEDURES
Switches and knobs on the overhead panel must be set as follows:
Generators ............................................................... IN
GPU ......................................................................... OUT
APU GEN................................................................. IN
BATT 1 & 2. ............................................................. OFF
Essential Power ....................................................... GUARDED
Bus Ties & Shed Buses ........................................... AUTO
Shed Buses must be set to OVRD to operate the recirculation
fans when the electrical system is energized by the APU
generator.
AC Power ................................................................. IN
Back-up.................................................................... IN
Avionics Master 1&2 ................................................ OUT
Emergency Lights .................................................... OFF
Fire Extinguishing Handle 1..................................... IN
Fuel Crossfeed......................................................... OFF
Pump Power 1&2 ..................................................... OFF
ICU Panel................................................................. OUT
Exterior Lights .......................................................... OFF
APU Fire Extinguishing ............................................ GUARDED
APU Master.............................................................. OFF
APU Fuel Shutoff ..................................................... GUARDED
Ignitions.................................................................... AUTO
Start/Stop Selectors ................................................. STOP
Fire Extinguishing Handle 2..................................... IN
Ailerons & Rudders Shutoff ..................................... IN
Engine Pump Shutoff ............................................... GUARDED
Electric Hydraulic Pumps......................................... OFF