ABNORMAL
PROCEDURES
ENGINE OUT
EICAS CAUTION: ENG1 (2) OUT
LIGHT: Master Caution
If during takeoff, above V
TAKEOFF WITH ENGINE
FAILURE Procedure ........................................... ACCOMPLISH
If in flight:
PRECAUTIONARY ENGINE
SHUTDOWN Procedure ..................................... ACCOMPLISH
ENGINE AIRSTART Procedure.................................... AS REQUIRED
TCAS............................................................................. TA ONLY
FADEC NOT DISPATCHABLE
EICAS CAUTION: FADEC ID NO DISP
LIGHT: Master Caution
Crew awareness.
ADC DATA FAIL
EICAS ADVISORY: E1 (2) ADC DATA FAIL
Confirm the failed side.
Associated FADEC ....................................................... RESET
If the message remains on:
Associated FADEC .................................................. ALTN
Check on EICAS that the associated FADEC in control has
changed.
If the message remains on:
Avoid unnecessary rapid thrust levers movement.
THRUST LEVER STOP FAILURE
EICAS ADVISORY: E1 (2) IDL STP FAIL
Be careful when reducing engines near IDLE.
NEVER SET THRUST LEVERS BELOW IDLE IN FLIGHT.
Page
1-03-45
14
AIRPLANE
OPERATIONS
MANUAL
and associated with an engine flameout:
1
Code
03
REVISION 40