HYDRAULIC POWER
BOTH HYDRAULIC SYSTEMS FAILURE
EICAS CAUTION: HYD SYS 1-2 FAIL, RUDDER SYS 1-2 INOP,
EICAS ADVISORY: E1-2 HYD PUMP FAIL
LIGHT: Master Caution
INDICATION: Hydraulic pressure indication on MFD may be amber.
Airspeed........................................................................ MAXIMUM
Check hydraulic systems fluid quantity:
If any hydraulic system fluid quantity is in green range:
Associated Electric Hydraulic Pump .................. ON
If any hydraulic system fluid quantity is in amber range:
Associated Electric Hydraulic Pump .................. OFF
CAUTION: DO NOT OPEN THE SPEED BRAKE.
If one system can be recovered, complete the appropriate procedure
for one hydraulic system failure.
If both systems remain inoperative:
Quick Disconnect Button ......................................... PRESS
Both Electric Hydraulic Pumps ................................ OFF
NOTE: The nose landing gear doors will open, therefore the pilot
should expect noise increase.
ABNORMAL LANDING GEAR
EXTENSION Procedure ..................................... ACCOMPLISH
Rudder and aileron are operating under mechanical reversion
mode. Expect greater rudder pedals and control wheels control
forces. Both pilots should act together to control the airplane, if
required. Consider the use of aileron and asymmetric thrust to help
in yaw control.
Land at the nearest suitable airport. Avoid landings at airports with
anticipated crosswind or turbulence. Perform a long final approach.
REVISION 36
AIRPLANE
OPERATIONS
MANUAL
AIL SYS 1-2 INOP
CONTINUES ON NEXT PAGE
ABNORMAL
PROCEDURES
250 KIAS
Page
1-03-48
1
Code
03

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMB145 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF