PNEUMATICS
AIR CONDITIONING
AND PRESSURIZATION
When the ECUs air supply is shut off in flight, the emergency ram air is
activated and the ram air valves are opened automatically, allowing
ram air to be routed to the distribution lines. Ram air may also be used
to ventilate the airplane interior for cabin smoke evacuation and cabin
ventilation purposes with the airplane depressurized and the ECUs
turned off.
NOTE: The Pneumatic System automatic logic closes the left Pack
Valve whenever the anti-icing system is operating below
24600 ft.