FIRE PROTECTION
BAGGAGE COMPARTMENT SMOKE DETECTOR
AIRPLANES PRE-MOD S.B. 145-26-0004
1 - BAGGAGE SMOKE DETECTOR OPERATION LIGHT (green)
Illuminates during normal system operation.
2 - BAGGAGE SMOKE DETECTOR RESET SWITCH
Cancels the EICAS message and resets the system for
operation.
3 - BAGGAGE SMOKE DETECTOR TEST SWITCH
When pressed (momentarily), simulates a smoke detection
condition and activates all associated alarms (red alarm light
and EICAS message).
During test, the green operation light extinguishes.
4 - BAGGAGE SMOKE DETECTOR ALARM LIGHT (red)
Illuminates in case of smoke detection inside the baggage
compartment.
BAGGAGE COMPARTMENT SMOKE DETECTOR
AIRPLANES POST-MOD S.B. 145-26-0004 OR S/N 145.119, 145.134
AND ON
Detectors are tested during Fire Detection System test.