KEY DIMENSIONS AND SPECIFICATIONS

Description
Rated Voltage/Frequency
Dimensions
Net Weight
Tub Capacity

CHOOSE THE PROPER LOCATION

WARNING
• Washer is heavy. Two or more people are required
when moving and unpacking the washer. Failure to do
so may result in damage to property or serious bodily
harm.
• Store and install the washer where it will not be
exposed to temperatures below freezing or exposed to
outdoor weather conditions. Failure to follow this
warning can cause serious injury, fire, electric shock, or
death.
• Properly ground washer to conform with all electric
governing codes and ordinances. Failure to follow this
warning can cause serious injury, fire, electric shock, or
death.
• To reduce the risk of electric shock, do not install the
washer in humid spaces. Failure to follow this warning
cancause serious injury, fire, electric shock, or death.
• To ensure proper air flow, do not block the large
opening on the bottom of the washer with carpeting or
other materials.
• Do not remove ground prong. Do not use an adapter
or extension cord. Plug into a grounded 3-prong outlet
Failure to follow this warning can cause serious injury,
fire, electric shock, or death.
NOTE: Installing the washer in a humid space, or
installing or storing the washer where it will be
exposed to the weather or freezing temperatures, may
result in rust or other damage that is not covered by
the product warranty.
Power Outlet
• The power outlet must be within 60 in. (1.5 m) of either side
of the washer.
• The appliance and outlet must be positioned so that the plug
is easily accessible.
• Do not overload the outlet with more than one appliance.
• The outlet must be grounded in accordance with current
wiring electric codes and regulations.
• Time-delay fuse or circuit breaker is recommended.
NOTE: It is the personal responsibility and obligation of the
product owner to have a proper outlet installed by a qualified
service technician.

INSTALLATION REQUIREMENTS

Top-Loading Washer
120VAC, 60Hz
27" W x 28 3/8" D x 45 3/4" H (59 1/4" H with lid open)
68.6 cm W x 72.3 cm D x 116 cm H (150.5 cm H with lid open)
136.7 lbs. (62.0kg)
4.5 cu. ft.

FLOORING

• To minimize noise and vibration, the washer MUST be
installed on a solidly constructed floor. See NOTE at bottom
of this page column.
• Allowable slope under the entire washer is a maximum
1 inch difference from side to side or from front to back.
• Installing on carpeting and soft tile surfaces is
not recommended.
• Never install the washer on a platform or weakly
supported structure.

CLEARANCES

A
B
A
Position
A
B
C
D
E
To ensure sufficient clearance for water lines and airflow, allow
minimum clearances of at least 1 in. (2.5 cm) at the sides and
4 in. (10 cm) behind the unit. Be sure to allow for wall, door, or
floor moldings that may increase the required clearances.
Minimum vertical space from floor to overhead
shelves, cabinets, ceilings, etc., is 56 in.
NOTE: The washer must be installed on firm flooring
to minimize vibration during the spin cycle. Concrete
flooring is best, but a wood floor is sufficient, provided
it is built to FHA (Federal Housing Administration)
standards. The washer should not be installed on rugs
or exposed to weather.
7
D
C
E
Dimension
1 inch (25 mm)
27 inch (686 mm)
28.5 inch (723 mm)
59 inch (1505 mm)
6 inch (150 mm)