ProBell System
System Information
ProBell
ProBell
System
This manual provides instructions on how to complete
the assembly of a cart-mounted ProBell Rotary
Applicator System, which includes the following
components.
Rotary Applicator
Applicator comes in various models.
• The Rotary
Rotary
Applicator
See the Models list for applicators that are available
with a system. Manuals 334452 or 334626 are the
main source of system information. They include
installation and operation instructions as well as
maintenance and repair information.
• The System
System Logic
System
Logic
Logic Controller
Controller
Controller controls and monitors
the rotary applicator system functions through
the user interface or through communication with
a PLC. A System Logic Controller is required if
your system includes a Speed Controller or an Air
Controller. Mount the System Logic Controller in
the non-hazardous area. Manual 3A3955 contains
all information needed to understand the setup and
operation of the system via the user interface. It
also contains detailed troubleshooting and event
code information.
Speed Controller
Controller directs the turbine air and
• The Speed
Speed
Controller
brake air to the applicator. The controller uses a
fiber optic signal from the ProBell applicator to
provide precise closed-loop control of the bell cup
rotation speed. The Speed Controller must be
mounted in the non-hazardous area, as close to
the applicator as possible to minimize pressure
loss in the air lines. Manual 3A3953 contains
specific installation, troubleshooting, repair, and
parts for this component.
Air Controller
Controller electronically controls the inner
• The Air
Air
Controller
and outer shaping air. It also provides air activation
signals for the paint, dump, and solvent (cup wash)
valves in the applicator. Mount the Air Controller in
the non-hazardous area, as close to the applicator
as possible to minimize pressure loss in the
air lines. See Manual 3A3954 for installation
instructions and features of each air controller,
specific installation, troubleshooting, repair, and
parts for this component.
Electrostatic Controller
Controller sends power to the
• The Electrostatic
Electrostatic
Controller
applicator power supply, which increases the
voltage to the level set at the controller. It must
be mounted in the non-hazardous area. See
ProBell Electrostatic Controller manual 3A3657
for all information needed to understand this user
interface.
• The Twenty
Twenty Meter
Twenty
Meter (65
Meter
(65 ft) ft) ft) Hose
(65
9 air lines, a fiber optic cable, power supply cable,
grounding cable, and 3 fluid lines (purchase fluid
lines separately for waterborne systems).
CGM (Communication Gateway Module)
• The CGM
CGM
provides a control link between the ProBell system
3A4232D
Information
Information
Hose Bundle
Hose
Bundle Kit
Bundle
Kit includes
Kit

ProBell System Information

and a selected field bus. This linkage provides
the means for remote monitoring and control by
external automation systems. The ProBell system
supports Modbus TCP, EtherNet/IP, DeviceNet,
and PROFINET. One gateway can support two
ProBells. System requires a ProBell system CGM
installation kit and gateway. See the following
tables.
Table
Table
Table 1 1 1 ProBell
ProBell System
ProBell
System CGM
System
Part Number
Field Bus
24Z574
All
Table 2 2 2 Communication
Communication Gateway
Table
Table
Communication
Part Number
Field Bus
DeviceNet
CGMDN0
DGMEP0
EtherNet/IP
DGMPN0
PROFINET
24W462
Modbus TCP
Electrical Inputs
Electrical
Electrical
Inputs and
Inputs
The following discrete I/O connections can be used
to drive the system remotely.
Speed Controller
Controller
Speed
Speed
Controller
• System status output
• Optional Interlock input
Electronic
Electronic
Electronic Air
Air
Air Controller
Controller
Controller
• Paint Trigger Input
• Optional Interlock Input
Electrostatic Controller
Electrostatic
Electrostatic
Controller
Controller
• Safe-to-Move Output
• Error Output
• Actual Spraying Current Output
• Actual Spraying Voltage Output
• Electrostatics Discharged Output
• SAFE POSITION Interlock Input
• 24 VDC Interlock Input
• System Interlock
• Electrostatic Enable Input
CGM Installation
CGM
Installation
Installation Kit
Kit
Kit
Manual
3A4384
Gateway Module
Module
Gateway
Module
Manual
312864
312864
312864
334183
and
and Outputs
Outputs
Outputs
9