KSB Etanorm FXV Installation & Operating Manual page 52

Sprinkler pump
Table of Contents

Advertisement

A B C D E F G H Possible cause
-
-
-
-
-
-
- Density or viscosity of fluid handled
-
-
-
-
-
-
- Use of unsuitable shaft seal materials
-
-
-
-
-
- Gland follower over-tightened or cocked Adjust.
-
✘ ✘
-
-
-
-
- Speed is too high.
-
-
-
-
-
-
- Tie bolts/sealing element defective
-
-
-
-
-
-
- Worn shaft seal
-
-
-
-
-
- Score marks or roughness on shaft
-
-
-
-
-
-
- Dismantle to find out.
-
-
-
-
-
-
- Vibrations during pump operation
-
-
-
-
✘ ✘
- Pump set is misaligned.
-
-
-
-
- Pump is warped or sympathetic
✘ ✘
-
-
-
-
-
-
- Increased axial thrust
-
-
-
-
-
-
- Insufficient or excessive quantity of
-
-
-
-
-
-
- Non-compliance with specified coupling
✘ ✘
-
-
-
-
-
- Motor is running on two phases only.
-
-
-
-
-
-
- Rotor out of balance
-
-
-
-
-
-
- Defective bearing(s)
-
-
-
-
-
✘ ✘ Flow rate is too low.
-
-
-
-
-
-
- Incorrect inflow of circulation liquid
52 of 62
8 Trouble-shooting
higher than stated in purchase order
protecting sleeve / shaft sleeve
vibrations in the piping.
10)
lubricant or unsuitable lubricant.
distance
Etanorm FXV
9)
Remedy
Contact the manufacturer.
Change the material combination.
10)
Reduce speed.
Fit new sealing element between volute
casing and casing cover.
Re-tighten the bolts.
Fit new shaft seal.
Check flushing liquid/barrier fluid.
Replace shaft protecting sleeve/shaft sleeve.
Fit new shaft seal.
Correct.
Fit new shaft seal, if required.
Correct the suction conditions.
Re-align the pump set.
Re-balance the impeller.
Increase pressure at the pump suction nozzle.
Re-align pump set.
Check the piping connections and secure
fixing of pump; if required, reduce distances
between the pipe clamps.
Fix the pipelines using anti-vibration material.
Clean balancing holes in the impeller.
Replace the casing wear rings.
Top up, reduce or change lubricant.
Correct the distance according to general
arrangement drawing.
Replace the defective fuse.
Check the electric cable connections.
Clean the impeller.
Re-balance the impeller.
Replace.
Increase the minimum flow rate.
Increase the free cross-section.
10)

Advertisement