KSB Etanorm FXV Installation & Operating Manual page 36

Sprinkler pump
Table of Contents

Advertisement

36 of 62
7 Servicing/Maintenance
If required, the bearings may be lubricated with greases of other soap bases.
Make sure to remove any old grease and rinse the bearings thoroughly.
7.2.3.1.3 Grease quantity
Table 12: Grease quantity per grease-lubricated DIN 625 radial ball bearing
Size
065-040-250
065-040-315
065-050-250
065-050-200
065-050-315
080-065-200
080-065-250
080-065-315
100-080-200
100-080-250
100-080-315
125-100-315
125-100-200
150-125-250
150-125-315
200-150-400
250-150-400
7.2.3.1.4 Changing the grease
CAUTION
Mixing greases of differing soap bases
Changed lubricating qualities!
▷ Thoroughly clean the bearings.
▷ Adjust the re-lubrication intervals to the grease used.
ü The pump has been dismantled for changing the grease.
1. Remove the outer cover plate of each bearing with a suitable tool. Dispose of
the cover plates.
2. Only half-fill the bearing cavities with grease.
Continue using the bearings without the outer cover plates (variant Z C3).
Etanorm FXV
Code
Grease quantity per
6305 2Z C3
6310 2Z C3
6305 2Z C3
6305 2Z C3
6310 2Z C3
6305 2Z C3
6307 2Z C3
6312 2Z C3
6307 2Z C3
6307 2Z C3
6312 2Z C3
6312 2Z C3
6307 Z C3
6312 2Z C3
6311 2Z C3
6311 2Z C3
6312 2Z C3
bearing
[g]
5
12
5
5
12
5
10
20
10
10
20
20
10
10
15
15
20

Advertisement