6. LOCAL CONFIGURATION

The Home Basic Edition can be configured locally using
the rotary switches and dip switches on the chargepoint.
Make sure that the charge point is not yet powered on
before configuring the features described in this chapter.
6.1 POWER SETTING
Select the maximum allowed current for the installed
circuit. Take the MCB, RCD, grid connection and local
regulations into account. Use table 1.1 to determine your
desired position of the left rotary switch, as indicated in
the '3.4.3 Overview Installing Accessories' section.
Rotary Position
Maximum
allowed current
0
16 A
1
20 A
2
25 A
3
32 A
4
16 A
5
20 A
6
25 A
7
32 A
Table 1.1: Maximum allowed current
INSTALLATIEHANDLEIDING – P15
INSTRUCTION MANUAL – P15 | P15
6.2 DYNAMIC POWER MANAGEMENT
SETTING
Enable Dynamic Power Management if the CT for 7,4
kW charge point or Dynamic Power Management
module for 22 kW charge point is installed. Use table
1.2 to determine your desired position of the right rotary
switch, as indicated in the '3.4.3 Overview Installing
Accessories' section. Select the maximum allowed
Dynamic Power Management current for the installed
circuit. Take the MCB, RCD, grid connection and local
regulations into account.
Rotary Position
0
1
2
3
4
5
6
7
8
9
A
B
C or greater
Table 1.2: Dynamic Power Management current
VERSION 0129NM02INT01
06A2NM20ENG05
Dynamic Power
Management current
Dynamic Power
Management disabled
16 A
20 A
25 A
32 A
35 A
40 A
50 A
63 A
70 A
80 A
90 A (7,4 kW model only)
100 A (7,4 kW model only)