The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the
gas part. The installation must be done observing the norms in force particularly concerning room ventilation and
discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
DIMENS.
MODEL
cm
PCA-94G
40x90x90h
PCA-98G
80x90x90h
PCA-912G
120x90x90h
CFA4-98G
80x90x90h
CFA6-712GV
120x90x90h
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
The equipment have a water inlet coupling at the back.
Always install an on-off valve between the appliance and the water mains, making sure it is easy to operate.
We also suggest installing a cartridge filter on the water inlet pipe.
Always connect to the cold water
Pressure included between 150 e 500 KPa (1,5÷5 bar)
Drainage for the water is at the back of the equipment and must be connected directly to the end of the stainless steel
drainpipe.
The drain must have no trap and be made in rigid pipes that can withstand a temperature of 100°C.
Under no circumstances must pipe diameter be reduced. The actual pipe should be at atmospheric pressure with the
appropriate funnel type air intake.
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
Installation rules
The installation and maintenance of the appliance must be done according to the correct procedures and regulation
texts in use, particularly:
• safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer's instructions and by qualified technicians and according to the regulations in effect. The electric wiring
shall conform to the regulations in effect. All fire prevention codes shall be observed.
GB
IT
DECLARATION OF COMPLIANCE
TECHNICAL DATA TABLE
NOMINAL BURNER
CAPACITY kW
Gas oven
5,5
8,5
GN2/1
1
1
/
2
2
/
3
3
/
2
2
8,5
3
3
8,5
INSTALLATION
PLUMBING – WATER INLET
PLUMBING – WATER DRAINAGE
CHECKING FOR CORRECT VENTILATION
IE
CH
TOTAL
Gas
NOMINAL
coupling
CAPACITY
ISO 7-1
kW
14
R 3/4"
28
R 3/4"
42
R 3/4"
36,5
R 3/4"
50,5
R 3/4"
30
Water
Water coupling
flow rate
P min = 150 Kpa
(regulable)
Pmax = 500 Kpa
lt/min.
4
R 3/4"
R 3/4"
4
R 3/4"
4
R 3/4"
4
R 3/4"
4