Program

Configuration settings are stored in non-volatile memory. Access
to each submenu is protected with passcode. To enter configuration
menu, hold  STOP for 8 seconds. In the menu, editing and storing
values is helped by flashing cursor.  START button moves cursor
one position to the right,  STOP button increments selected digit
by one, cycles between options, or scrolls to the next screen when
the cursor is at the '>' symbol.
Configuration menu layout is shown below.
MENU
1. SETTINGS
Settings and calibration passcode prompt
1. High pressure pump delay, s
2. Forward Flush 1 duration, s
3. Forward Flush 2 duration, s
4. High pressure pump power during Forward Flush 2, on/off
5. Frequency of periodic Forward Flush in Service, h
6. Frequency of periodic Forward Flush in Standby, h
7. Read low feed pressure during Forward Flush, on/off
8. Low feed pressure switch, NO/NC
9. Low feed pressure Fault delay, s
10. High feed pressure switch, NO/NC
11. Permeate backpressure switch, NO/NC
12. Backpressure Standby delay, s
13. Tank level switch, NO/NC
14. Tank level Standby delay, s
15. 0...1000 μS/cm conductivity range, on/off
16. 0...50 μS/cm conductivity range, on/off
17. Permeate conductivity Fault threshold, μS/cm
18. Permeate conductivity Fault delay, s
19. Temperature probe, on/off
1.21 New settings and calibration passcode
O
L
L
E
R
O
L
L
E
R
1. Set permeate temperature, °C (if 1.19 is set to 'off')
2. Display real temperature, on/off (if 1.19 is set to 'on')
Factory Setting
0000
10 sec
60 sec
0 sec
off
4 hour
24 hour
on
NC
3 sec
NO
NC
1 sec
NC
1 sec
on
off
0 uS/cm
on
on
23