Program
Configuration settings are stored in non-volatile memory. Access
to each submenu is protected with passcode. To enter configuration
menu, hold STOP for 8 seconds. In the menu, editing and storing
values is helped by flashing cursor. START button moves cursor
one position to the right, STOP button increments selected digit
by one, cycles between options, or scrolls to the next screen when
the cursor is at the '>' symbol.
Configuration menu layout is shown below.
MENU
1. SETTINGS
Settings and calibration passcode prompt
1. High pressure pump delay, s
2. Forward Flush 1 duration, s
3. Forward Flush 2 duration, s
4. High pressure pump power during Forward Flush 2, on/off
5. Frequency of periodic Forward Flush in Service, h
6. Frequency of periodic Forward Flush in Standby, h
7. Read low feed pressure during Forward Flush, on/off
8. Low feed pressure switch, NO/NC
9. Low feed pressure Fault delay, s
10. High feed pressure switch, NO/NC
11. Permeate backpressure switch, NO/NC
12. Backpressure Standby delay, s
13. Tank level switch, NO/NC
14. Tank level Standby delay, s
15. 0...1000 μS/cm conductivity range, on/off
16. 0...50 μS/cm conductivity range, on/off
17. Permeate conductivity Fault threshold, μS/cm
18. Permeate conductivity Fault delay, s
19. Temperature probe, on/off
1.21 New settings and calibration passcode
O
L
L
E
R
O
L
L
E
R
1. Set permeate temperature, °C (if 1.19 is set to 'off')
2. Display real temperature, on/off (if 1.19 is set to 'on')
Factory Setting
0000
10 sec
60 sec
0 sec
off
4 hour
24 hour
on
NC
3 sec
NO
NC
1 sec
NC
1 sec
on
off
0 uS/cm
on
on
23