Model And Suffix Codes - YOKOGAWA OR8EFG User Manual

Kcl filling type orp sensor
Table of Contents

Advertisement

1.2
Model and Suffix codes
ORP Sensor
l
Model
OR8EFG
Electrode
Cable Length
and KCl Tube
Length
KCl Reserve Tank (*1)
Measuring System
Style
Option
*1:
2-inch pipe mounting bracket is supplied with TT1, TT2.
Only a supply tube, but no KCl solution, is supplied with TN1 and TN2.
Since a KCl solution is not supplied with TT2, arrange it from among accessories or auxiliary parts.
*2:
Prepare an air pressure regulator as shown in the diagram below when the medium-pressure reserve tank is used.
To ORP Sensor, Regulator, (to be prepared separately)
To ORP sensor
*3:
Mark band is shown by alphanumeric and fork terminals are used.
*4:
Mark band is shown by numeral and pin terminals are used.
*5:
Mark band is shown by numeral and M4 ring terminals are used.
When terminal box is used, select WTB10-PH5.
*6:
The tag which indicated the color, the sign, and the number is attached to the cable of a sensor.
*7:
Mark band is shown by numeral and M3 ring terminals are used.
When terminal box is used, select WTB10-PH3.
*8:
Choose when using in the heavily contaminated application.
Accessories
l
Model
OR8AX
Style
Option (*2)
*1:
Including the following:
Two 200 mL polyethylene cups
One cleaning bottle
One pack of quinhydrone reagent powder (three bags, 250 mL solution each)
One 250 mL polyethylene bottle
*2:
Either /KCLL or /KCLP is required for OR8EFG-¨¨-¨¨-TT2.
Suffix Code
.........................................
-AU
-PT
-03
-05
-07
-10
-15
-20
-TT1
-TT2
-TN1
-TN2
-N
-E
-F
-B
-G
*A
Special junction
Air Supply
Regulator
(to be prepared separately)
Suffix Code Option Code
..................... ...................... Accessories for ORP meter (*1)
*A
...................... Style A
/STD
/KCLL
/KCLP
/TMP
< 1. Specification >
Option Code
...................
KCl Filling Type ORP Sensor
...................
Gold
...................
Platinum
...................
3 m
...................
5 m
...................
7 m
...................
10 m
...................
15 m
...................
20 m
...................
For general purpose (250 mL solution inlet)
...................
For medium pressure (*2)
...................
For maintenance (for TT1)
...................
For maintenance (for TT2)
...................
For OR200,OR400 (*3)
...................
For FLXA402,PH202,FLXA202,FLXA21 (*4)
...................
For FLXA202,FLXA21 (*5)
...................
For OR100 (*6)
...................
For FLXA402, PH450G,PH202/TB (*7)
...................
Style A
/TF
PTFE junction (*8)
Description
Sensor stand (with mounting bracket for 2-inch pipe)
KCl solution (one 250 mL polyethylene bottle)
KCl powder (three bags, 250 mL solution each)
Thermometer (0 to 100°C)
Description