Electrically Connecting The Outdoor Unit - Baxi SPC SPLIT Installation And Service Manual

Thermodynamic water heater
Table of Contents

Advertisement

6 Installation
Fig.53
2
5
1
2
1 Control panel electrical cable
2 General electrical cable of the outdoor unit
3 Immersion heater electrical cable
54
SPC Split
6.5.3
3
4
3
The 3G power supply cable of a maximum length of 20 m and a 2.5 mm²
section to connect the outdoor unit, is provided by the installer.
1. Remove the service panel from the outdoor unit in order to access the
2. Connect the general power supply cable to the appropriate terminals.
3. Connect the immersion heater power supply cable to the appropriate
4. Secure the mains power supply cables with the traction arrester.
5. Connect the control panel power supply cable to the appropriate
6. Connect the domestic hot water tank temperature sensor connector to
7. Connect the off-peak/peak rate connector to the appropriate terminals,
8. Replace the service panel passing the cables through the passage

Electrically connecting the outdoor unit

5
7
6
1
MW-2000629-1
4 Temperature sensor cable
5 Peak/off-peak rate cable
electrical terminal block.
terminals.
terminals.
the appropriate terminals.
in the case where the off-peak signal is to be used.
provided for this purpose in the panel.
4
7740321 - v04 - 03122019
8