Installation; General; Preparation; Levelling The Domestic Hot Water Tank - Baxi SPC SPLIT Installation And Service Manual

Thermodynamic water heater
Table of Contents

Advertisement

6

Installation

6.1

General

6.2

Preparation

Fig.28
Levelling
A
(x3)
MW-4000124-1
Fig.29
1
MW-4000125-2
7740321 - v04 - 03122019
6.2.1
The domestic hot water tank is levelled using three feet screwed onto the
base of the appliance.
1. Screw on the adjustable feet A.
2. Return the domestic hot water tank to the vertical position.
3. Adjust the height of the feet with a spanner.
6.2.2
All the screws and dowels required for installing the control panel are
supplied.
1. Open the control panel by unclipping the cover on the wall bracket.
2. Place the box horizontally against the wall and check its position with
a spirit level.
2
3. Use a pencil to mark the positions for the mounting screws.
3
Caution
Installation of the heat pump must be done by a qualified
professional in accordance with prevailing local and national
regulations.

Levelling the domestic hot water tank

Important
The adjustable feet are provided in the instructions bag.
Important
Adjustment range: 4 to 21 mm:
Use metal blocks under the feet of the domestic hot water tank if
necessary.
Caution
Do not place the blocks on the exterior sides of the domestic hot
water tank.

Installing the control panel

6 Installation
SPC Split
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spc split 200 fsSpc split 300 fs

Table of Contents