4 Description of the product

4
Description of the product
4.1

General description

4.2

Operating principle

Fig.7
Schematic diagram
1
8
2
7 4 5 3
24
SPC Split
The thermodynamic water heaters in the SPC SPLIT range have the
following specifications:
The domestic hot water tank can be heated by:
4.2.1
The thermodynamic water heater uses the outside air to produce domestic
hot water.
The refrigerant circuit is a closed circuit in which the R134a refrigerant
plays the role of an energy carrier.
The heat from the intake air is transferred to the refrigerant in the finned
heat exchanger at a low evaporation temperature.
The refrigerant is drawn in in vapour form by a compressor, which raises it
to a higher pressure and temperature and sends it to the condenser. In the
condenser, the heat extracted in the evaporator and some of the energy
absorbed by the compressor are released into the water.
The refrigerant is depressurised in the expansion valve and then cooled.
The refrigerant fluid can again extract the heat contained in the intake air
from the evaporator.
1
2
3
4
5
6
7
8
6
MW-4000108-1
Floor-standing thermodynamic storage water heater,
Heat pump extracting energy from the outside air,
Control panel used to:
display the domestic hot water temperature,
adjust the timer program.
1.6 kW steatite immersion heater,
Glass-lined tank protected by magnesium anode,
Very thick insulation (0% CFCs).
The outdoor unit,
The immersion heater (up to 75°C).
For more information, see
Limit temperatures of the thermodynamic water heater, page 26

Thermodynamic water heater

Domestic hot water tank
Outdoor unit
Condenser
Evaporator
Compressor
Expansion valve
Fan
Air flow
7740321 - v04 - 03122019