For connections, interrupt the loop and use the same wires to connect to the detector.
Inputs may be programmed as NC, NO, single balance and double balance. Both inputs can manage fast
signals from seismic or roller blink sensors. Connection mode is NC type fixed in this case.
WARNING! "Double balance" is the only EN50131 compliant connection mode. Refer to the manuals of
1067 and 1068 series control units for further, more detailed information.
DEVICE ACQUISITION
KEY CUSTOMISATION
Key customisation may be useful, for example, to associate a key with limited operation. The key can be
rapidly identified by inserting the coloured bulbs provided in the seats on the key.

TECHNICAL SPECIFICATIONS

Rated supply voltage (picked by the control panel through the communication bus) ........................13.8 V
Operating voltage min/max .................................................................................................... 9 V
Rated current absorption at 13.8 V
LEDs OFF ..................................................................................................................................... 33 mA
All LEDs ON .................................................................................................................................. 36 mA
Auxiliary inputs ........................................................................................................................................... 2
Degree of protection of casing ..................................................................................................... IP40 / IK02
Operating temperature............................................................................................................. -10°C ÷ 40°C
Dimensions (W x H x D) ..................................................................................................... 50 x 40 x 22 mm
Symbol
Direct input voltage.
See the installation manual of the device.
4
The reader can be acquired by pressing the dedicate button.
For details on the acquisition procedure, refer to the control panel installation
manual.
To display the reader address, press the button and count the blink of the yellow
LED.
:
Description
EN50131
÷ 15 V