TOTAL ARMING AND DISARMING
Approach the key to approximately 1 cm from the proximity reader and move it away when the yellow LED
blinks. The 3 green LEDs indicate the state of the monitored zones: LED on corresponds to zone active. If
multiple zones are associated with a LED, the LED will blink when they are not all armed. The possibility of
activation of each zone depends on the programming of the reader and the key used.

PARTIAL ARMING

Approach the key to approximately 1 cm from the proximity reader, hold it in the position for at least 3
seconds and move it away when the green LEDs blink. The reader will show the various partial arming
combinations starting from the last one after a few instants. To confirm the choice hold the Key. The LEDs
indicate the armed zones.
NOTE: If you use a key is not acquired (key not recognized), the green LED will blink rapidly.

INSTALLATION

The reader can be installed on Bticino Magic frames using the adapter provided on Simon Urmet nea
frames. Optional adapter frames for other wiring systems are available.
NOTE: Multiple readers can be installed side by side providing their address number is sequential (reader
1, reader 2, etc.
CONNECTIONS
A 4-wire bus is used to connect to the control panel.
The total length of all bus stretches must not exceed 400 m.
Wires with cross-section area of 0.5 mm
crosssection area smaller than 0.5 mm

ALARM INPUTS

DS1068-002B
2
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
The device has two freely programmable alarm inputs.
The two inputs are provided closed with two different colour wires as standard.
The yellow wire identifies input 1, the green wire identifies input 2.
Connect the tamper of input 1 of the reader (yellow wire: cut the wire and
connect the two pieces to the tamper). TAMPER is the default factory setting.
Connect another device, if required, to input 2 (green wire: cut the wire and
connect the two pieces to the device).